SICK I150 Rope Pull Switch 203 mm, 3 NC/1 NO

小計(1 件)*

TWD9,832.00

(不含稅)

TWD10,323.60

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 1 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD9,832.00

* 參考價格

RS庫存編號:
285-9587
製造零件編號:
I150-RP313 / 6024883
製造商:
SICK
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SICK

Product Type

Rope Pull Switch

Contact Configuration

3 NC/1 NO

IP Rating

IP65

Series

I150

Minimum Operating Temperature

-25°C

Contact DC Voltage

24V dc

Contact AC Voltage

240V ac

Contact Current

3A

Maximum Operating Temperature

80°C

Standards/Approvals

China RoHS, cULus, EU DoC, IEC, UKCA

Width

85mm

Length

203mm

Depth

69mm

Housing Material

Metal

Hazardous Area Certification

No

Conduit Entry

M20

Mechanical Life

106Cycles

COO (Country of Origin):
DO

SICK I150 Series Rope Pull Switch, 203mm Length, Metal Housing - I150-RP313 / 6024883


This rope pull switch is a manually operated safety device designed to stop machinery by pulling a rope up to 75m long. It is intended for industrial safety applications where a linear actuator along a rope line provides a Rapid stop command. The enclosure is rated to IP65 for protection against dust and water ingress and is suitable for environments with ambient temperatures from -25°C to +80°C.

Features and Benefits:


• 3NC/1NO contacts provide distinct safety signalling capability
• 3A rated current supports 240V AC switching requirements
• Die-cast lightweight metal housing delivers robust mounting options
• Mechanical life 1x10^6 switching cycles enables prolonged service
• M20 cable gland permits standard conduit entry installation

Applications


• Suitable for emergency stop lines on conveyor systems
• Ideal for long-span rope actuation up to 75m
• Used with safety logic units for monitored stop functions
• Can be used for perimeter guarding of production lines
• Suitable for retrofit where metal-housed stops are required

How is fault detection handled for this device?


The switch lacks internal fault detection, so connected safety logic must detect faults.

What electrical ratings support control wiring choices?


It supports AC-15/DC-13 usage with 3A at 240V AC and 2A at 24V DC switching.

What environmental conditions can it withstand?


The unit operates and is stored between -25°C and +80°C and meets IP65 enclosure protection.

What wiring and conductor sizes are compatible?


Connection is via three M20 cable glands accepting conductors up to 1.5mm².

What switching principle and minimum switching thresholds apply?


It uses a slow-action switching element with switching voltage ≥5V DC and minimum switching current 5mA.