SICK I150 Rope Pull Switch 203 mm, 2 NC/2 NO

小計(1 件)*

TWD9,832.00

(不含稅)

TWD10,323.60

(含稅)

Add to Basket
選擇或輸入數量
庫存資訊目前無法存取 - 請稍後再回來查看
單位
每單位
1 +TWD9,832.00

* 參考價格

RS庫存編號:
285-9586
製造零件編號:
I150-RP223 / 6024884
製造商:
SICK
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SICK

Product Type

Rope Pull Switch

Contact Configuration

2 NC/2 NO

IP Rating

IP65

Number of Cable Entries

3

Series

I150

Contact DC Voltage

24V dc

Minimum Operating Temperature

-25°C

Contact AC Voltage

240V ac

Contact Current

3A

Maximum Operating Temperature

80°C

Length

203mm

Depth

69mm

Housing Material

Metal

Width

85mm

Standards/Approvals

China RoHS, cULus, EU DoC, IEC, UKCA

Hazardous Area Certification

No

Mechanical Life

106Cycles

Conduit Entry

M20

COO (Country of Origin):
DO

SICK I150 Series Rope Pull Switch, 203mm Length, Metal Housing - I150-RP223 / 6024884


This rope pull switch provides a manual safety command solution for industrial operations where a pull-cord emergency stop is required. Designed for heavy-duty environments, it features a die-cast lightweight metal enclosure with a varnished finish and an ingress protection rating suitable for exposed locations. The unit interfaces via three M20 cable glands and is intended to be integrated with a separate safety logic unit for fault monitoring.

Features and Benefits:


• IP65-rated enclosure for protection in harsh environments
• 2NC and 2NO contacts delivering positive-action switching
• Rated for 3A at 240V AC and 2A at 24V DC switching
• Mechanical life rated to 1e6 switching cycles for longevity
• Operates across -25 to 80°C for varied ambient conditions

Applications


• Suitable for emergency-stop rope switch installations on conveyors
• Used for perimeter pull-cord guarding on production lines
• Ideal for long-span pull-cord systems up to 75m length
• Used with machine-safety logic units for diagnostic monitoring
• Suitable for integration where multiple cable entries are required

How is the device connected electrically?


It accepts conductors up to 1.5mm² via three M20 cable entries using cable glands.

What contact behaviour should be expected during actuation?


The device uses slow-action switching elements with positive-action N/C and N/O contacts.

How is fault detection handled in a safety circuit?


The switch has no internal fault detection and relies on the connected safety-related logic unit for diagnostics.

What are the insulation and withstand ratings for electrical stress?


The rated insulation voltage is Ui 250V and the impulse withstand voltage is Uimp 2,500V.

相關連結

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。