SICK STR1 Safety Interlock Switch, RFID, Vistal

暫時無法供應
抱歉,我們不知道何時會到貨。
RS庫存編號:
285-9020
製造零件編號:
STR1-SAXM0AC8
製造商:
SICK
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SICK

Lock Style

RFID

Product Type

Safety Interlock Switch

Actuator Included

No

Safety Contacts

2

Housing Material

Vistal

Series

STR1

Minimum Operating Temperature

-30°C

Contact AC Voltage

230V ac

Number of Auxiliary Contacts

1

Switch Contact Current

100mA

IP Rating

IP69K, IP67

Contact DC Voltage

24V dc

Maximum Operating Temperature

70°C

Hazardous Area Certification

No

Length

18mm

Number of Head Directions

5

Depth

26mm

Width

40mm

Standards/Approvals

IEC 60529

COO (Country of Origin):
MY

SICK STR1 Series Safety Interlock Switch, 24V DC Supply Voltage, 230V AC Contact AC Voltage - STR1-SAXM0AC8


This safety interlock switch is a non-contact RFID device designed to monitor access points and protect machinery by providing two safe outputs. It operates on a 24V DC supply and interfaces via an 8-pin M12 cable connection for integration with safety controllers. The unit is suitable for demanding industrial environments where sealed protection and multi-directional sensing are required.

Features and Benefits:


• SIL3 safety rating provides high-integrity risk reduction
• IP69K protection enables washdown and high-pressure cleaning
• Two safety outputs with 100mA limit support safe shutdown
• Active sensing on three surfaces allows flexible actuation
• Self-monitoring OSSD outputs enable series connection diagnostics

Applications


• Suitable for machine guarding in food processing environments
• Ideal for corrosive washdown areas requiring IP69K protection
• Used with safety controllers for series-connected access monitoring
• Can be used for multi-directional guard doors and flaps
• Suitable for installations needing a Compact 18mm height profile

What electrical interfaces are available for integration?


It uses an 8-pin M12 cable with a 0.2m attached lead and supports long connecting cables up to 200m.

How does the device indicate status and diagnostics?


LEDs provide status display and diagnostic indication for operator feedback.

What environmental temperatures can it withstand during operation?


It operates between -30°C and +70°C for units with qualifying serial numbers

alternate serial ranges use -10°C to +70°C.

Which materials and ratings support washdown suitability?


The housing is VISTAL® and the enclosure rating meets IP67 and IP69K standards.

How are safe outputs arranged and controlled?


Two self-monitoring semiconductor outputs (OSSDs) are provided with complementary auxiliary contact behaviour for enable inputs.