SICK TR4 Safety Interlock Switch, RFID, Vistal

小計(1 件)*

TWD10,748.00

(不含稅)

TWD11,285.40

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 5 件準備從其他地點送貨
  • 加上 7 件從 2026年12月09日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD10,748.00

* 參考價格

RS庫存編號:
285-9063
製造零件編號:
TR4-SDM10PB
製造商:
SICK
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SICK

Lock Style

RFID

Product Type

Safety Interlock Switch

Actuator Included

No

Safety Contacts

2

Housing Material

Vistal

Series

TR4

Contact AC Voltage

230V ac

Minimum Operating Temperature

-25°C

IP Rating

IP69K, IP67

Switch Contact Current

200mA

Contact DC Voltage

24V dc

Maximum Operating Temperature

70°C

Hazardous Area Certification

No

Number of Head Directions

5

Depth

20mm

Length

88mm

Width

25mm

Standards/Approvals

IEC 60529

COO (Country of Origin):
DO

SICK TR4 Series Safety Interlock Switch, 24V DC Supply, IP67 - TR4-SDM10PB


This safety interlock switch is a non-contact RFID device designed to monitor access points and protect personnel in industrial settings. It operates from a 24V DC supply and provides two safely monitored semiconductor outputs for integration into safety circuits. The unit is suited to control-cabinet wiring with diagnostic capability and is built to withstand harsh environments and routine industrial stresses.

Features and Benefits:


• SIL 3 safety level delivering high-integrity protection
• Category 4 safety enabling Advanced risk reduction
• PFHD 6.03e-10 offering quantifiable failure metrics
• 10m cable with long-run capability to 200m reducing wiring changes
• Self-monitoring OSSD outputs limiting external fault propagation

Applications


• Suitable for machine-guard monitoring in manufacturing lines
• Ideal for food-industry washdown environments requiring IP69K
• Used with safety controllers needing PL e performance
• Can be used for access control on automated cells
• Suitable for installations requiring vibration and shock resilience

What temperatures can it operate within?


It functions across an ambient range of -25°C to +70°C.

How are status indications provided on the device?


Built-in LEDs provide Visual status and diagnostic indication.

What electrical loads can the outputs drive?


Each semiconductor output supplies up to 200mA and accepts 24V DC control voltage.

How is the unit connected and what cable characteristics apply?


It uses a 10m PVC-sheathed cable, 6.5mm diameter, 0.25mm² conductors with specified bend radii.

相關連結

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。