SICK STR1 Safety Switch, RFID Actuator Included, Vistal, Electronic

小計(1 件)*

TWD10,596.00

(不含稅)

TWD11,125.80

(含稅)

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2026年12月21日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD10,596.00

* 參考價格

RS庫存編號:
285-4299
製造零件編號:
STR1-SASU10P5
製造商:
SICK
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SICK

Product Type

Safety Switch

Lock Style

RFID

Lock Type

Electronic

Actuator Included

Yes

Safety Contacts

1

Housing Material

Vistal

Series

STR1

Minimum Operating Temperature

-30°C

IP Rating

IP69K, IP67

Contact DC Voltage

24V dc

Switch Contact Current

100mA

Contact AC Voltage

230V ac

Maximum Operating Temperature

70°C

Hazardous Area Certification

No

Depth

26mm

Standards/Approvals

IEC 60529

Number of Head Directions

5

Width

40mm

Length

18mm

COO (Country of Origin):
MY

SICK STR1 Series Safety Switch, 24V DC Supply Voltage, IP69K - STR1-SASU10P5


This safety switch is a non-contact RFID sensor and actuator system designed to monitor protective guards and access points in industrial settings. It provides safety outputs and diagnostics for individual wiring applications, operates from a 24V DC supply and is housed in a robust VISTAL® enclosure to suit harsh environments.

Features and Benefits:


• SIL3 safety integrity delivers high-risk functional protection
• Two safe outputs enable redundant safety signalling
• Output current limited to 100mA for controlled switching
• Operating range accommodates temperatures up to 70°C
• IP69K and IP67 rating resists washdown and dust ingress

Applications


• Suitable for food-industry washdown environments requiring IP69K
• Used with guarded machines needing redundant safety outputs
• Ideal for assembly lines requiring non-contact interlocks
• Can be used where compact, high-temperature sensors are needed
• Suitable for systems needing cable connection with diagnostics

What connection options are provided for integration?


It uses a 5-wire cable with a 10m factory-fitted lead and allows long connecting cables up to 200m.

How is actuator alignment and direction handled?


The device supports five actuation directions and three Active sensor surfaces on TOP and both sides for versatile alignment.

What safety categories and performance levels does it meet?


It is specified to Category 4 and Performance Level PLe with a PFHD of 5.1x10-9 and a 20-year mission time.

How are faults and status indicated?


Built-in LEDs provide status display and diagnostics for detection of internal or external faults.

What are the electrical timing characteristics relevant to system design?


Response time is 40 MS, release time on approach is 100 MS, risk detection time is 80 MS and switch-on time is 2.5 s.