SICK STR1 Safety Interlock Switch Actuator Included, Vistal

小計(1 件)*

TWD7,896.00

(不含稅)

TWD8,290.80

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 1 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD7,896.00

* 參考價格

RS庫存編號:
285-9014
製造零件編號:
STR1-SAFM10P5
製造商:
SICK
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SICK

Product Type

Safety Interlock Switch

Actuator Included

Yes

Safety Contacts

2

Housing Material

Vistal

Series

STR1

IP Rating

IP69K, IP67

Contact AC Voltage

230V ac

Contact DC Voltage

24V dc

Minimum Operating Temperature

-30°C

Number of Auxiliary Contacts

1

Switch Contact Current

100mA

Hazardous Area Certification

No

Maximum Operating Temperature

70°C

Depth

26mm

Length

18mm

Number of Head Directions

5

Width

40mm

Standards/Approvals

CE

COO (Country of Origin):
MY

SICK STR1 Series Safety Interlock Switch, IP69K, VISTAL Housing - STR1-SAFM10P5


This safety interlock switch is a non-contact RFID sensor and actuator system designed to monitor access points in industrial automation. It delivers safety outputs via self-monitoring semiconductor outputs and an auxiliary contact while operating from a 24V DC supply. The unit is intended for harsh environments with high ingress protection and works across a wide ambient temperature range for continuous machine-safety applications.

Features and Benefits:


• SIL3 safety integrity for high-demand safety applications
• Category 4 performance level PL e for functional safety compliance
• Dual safe outputs provide redundant fault-tolerant switching
• 10m cable length enabling flexible installation distances
• IP69K-rated enclosure resists high-pressure washdown

Applications


• Suitable for guarding on automated assembly lines
• Ideal for washdown areas in food-processing plants
• Used with safety Gates on robotic workcells
• Can be used for perimeter access monitoring in manufacturing
• Suitable for machine-tool enclosures requiring Compact switches

What supply voltage range does it accept?


It operates from a 24V DC supply within a 19.2V DC to 28.8V DC window.

How are the outputs configured for safety circuitry?


It provides two self-monitoring semiconductor outputs that are supervised and an auxiliary contact with complementary switching.

What environmental stresses can it tolerate?


The device meets IP67 and IP69K protection and withstands vibration 10Hz to 55Hz, 1mm and shock 30g, 11 ms.

How long is the cable and what is its construction?


It has a 10m PVC-sheathed cable with copper conductors and 0.12mm² cross-section.

What response timing should be expected for safety reactions?


Typical response time is 40 MS, release time 100 MS, and an 80 MS fault-detection interval.

相關連結

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。