SICK STR1 Safety Interlock Switch, RFID, Vistal

小計(1 件)*

TWD5,400.00

(不含稅)

TWD5,670.00

(含稅)

Add to Basket
選擇或輸入數量
有限的庫存
  • 2 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD5,400.00

* 參考價格

RS庫存編號:
285-9019
製造零件編號:
STR1-SAXM0AC5
製造商:
SICK
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SICK

Lock Style

RFID

Product Type

Safety Interlock Switch

Actuator Included

No

Safety Contacts

2

Housing Material

Vistal

Series

STR1

IP Rating

IP69K, IP67

Switch Contact Current

100mA

Contact AC Voltage

230V ac

Minimum Operating Temperature

-30°C

Contact DC Voltage

24V dc

Number of Auxiliary Contacts

1

Maximum Operating Temperature

70°C

Hazardous Area Certification

No

Standards/Approvals

IEC 60529

Width

40mm

Number of Head Directions

5

Depth

26mm

Length

18mm

COO (Country of Origin):
MY

SICK STR1 Series Safety Interlock Switch, 2 Safety Contacts, 24V DC Supply - STR1-SAXM0AC5


This safety interlock switch is a non-contact RFID device designed to monitor access points in safety-critical installations. It provides two safe outputs and one auxiliary switching contact for machine guarding and perimeter protection, operating from a 24V DC supply. The unit is suited to harsh environments with high ingress protection and functions across a wide ambient temperature range.

Features and Benefits:


• SIL 3 safety level delivering high functional integrity
• Category 4 performance enabling demanding safety architectures
• IP69K and IP67 rating allowing high-pressure washdowns
• 100mA output current supporting low-power safety circuits
• 0.2m cable with M12 plug facilitating Compact connections

Applications


• Suitable for food production line washdown zones
• Used with safety controllers in automated cells
• Ideal for perimeter guarding on packaging machinery
• Can be used for series connection with diagnostics
• Used for access monitoring in harsh manufacturing environments

What type of actuator is required for correct operation?


It operates with universally coded RFID actuators and supports multiple actuator styles.

How does the device indicate status and diagnostics?


LED indicators provide status and diagnostic feedback for on-site checks.

What are the electrical Interface and connector details?


It uses a 5-pin M12 connection with a 0.2m cable and class 2 classification.

How does the unit behave after power is applied?


The device requires a switch-on time of 2.5 s and adds 0.1 s per sensor in series.

What mechanical resilience does the device offer against shock and vibration?


It withstands vibration at 10Hz to 55Hz with 1mm amplitude and shock up to 30g, 11 ms.

相關連結

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。