SICK i10 Safety Interlock Switch, Fibreglass Reinforced Thermoplastic

小計(1 件)*

TWD1,769.00

(不含稅)

TWD1,857.45

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 53 件準備從其他地點送貨
  • 加上 9 件從 2026年11月30日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD1,769.00

* 參考價格

RS庫存編號:
285-9568
製造零件編號:
i10-RA213
製造商:
SICK
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SICK

Product Type

Safety Interlock Switch

Actuator Included

No

Safety Contacts

1 NO, 2 NC

Housing Material

Fibreglass Reinforced Thermoplastic

Series

i10

IP Rating

IP66

Switch Contact Current

3A

Contact AC Voltage

240V ac

Contact DC Voltage

24V dc

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

80°C

Hazardous Area Certification

No

Width

31mm

Standards/Approvals

IEC 60529

Length

112mm

Number of Head Directions

4

Depth

50mm

COO (Country of Origin):
TW

SICK i10 Series Safety Interlock Switch, 3A Rated Current, IP66 - i10-RA213


This safety interlock switch is an electro-mechanical device designed to monitor and secure movable guards in industrial settings. It operates with a slow-action switching element and requires a separate safety logic unit for fault monitoring. The unit is intended for non-hazardous areas and offers a sealed enclosure suitable for environments exposed to dust and water.

Features and Benefits:


• 1NO 2NC safety contacts deliver clear state signalling
• 3A rated current enables 240V AC and 24V DC operation
• IP66 enclosure rating protects against dust and powerful water jets
• Fibreglass-reinforced thermoplastic housing resists mechanical wear
• Four-direction actuator head allows flexible approach angles

Applications


• Suitable for guarding machine access points in factories
• Ideal for integration with safety control units and relays
• Used with interlocked doors on conveyor and packaging lines
• Can be used for perimeter access monitoring in assembly cells

What electrical switching limits should installers observe?


The contacts are rated 3A for both 240V AC and 24V DC and require short-circuit protection F15.

How should fault detection be handled for safety functions?


The device lacks internal fault monitoring so a connected safety-related logic unit must perform all diagnostics.

What environmental temperatures can the unit tolerate?


It operates reliably between -25°C and +80°C and shares the same range for storage.

What mechanical durability can users expect from repeated operation?


The switch provides a mechanical life of 10 x 10^6 switching cycles and a B10d Value of 2 x 10^6 switching cycles under small loads.