規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | SICK | |
| Lock Style | Power | |
| Product Type | Safety Interlock Switch | |
| Lock Type | Electromagnetic | |
| Actuator Included | No | |
| Safety Contacts | 2 NC | |
| Housing Material | Fibreglass Reinforced Thermoplastic | |
| Series | i10 | |
| Contact DC Voltage | 24V dc | |
| Minimum Operating Temperature | -20°C | |
| IP Rating | IP67 | |
| Contact AC Voltage | 230V ac | |
| Switch Contact Current | 4A | |
| Maximum Operating Temperature | 55°C | |
| Hazardous Area Certification | No | |
| Width | 42mm | |
| Number of Head Directions | 4 | |
| Length | 192mm | |
| Standards/Approvals | IEC 60529 | |
| Depth | 40mm | |
| 選取全部 | ||
|---|---|---|
品牌 SICK | ||
Lock Style Power | ||
Product Type Safety Interlock Switch | ||
Lock Type Electromagnetic | ||
Actuator Included No | ||
Safety Contacts 2 NC | ||
Housing Material Fibreglass Reinforced Thermoplastic | ||
Series i10 | ||
Contact DC Voltage 24V dc | ||
Minimum Operating Temperature -20°C | ||
IP Rating IP67 | ||
Contact AC Voltage 230V ac | ||
Switch Contact Current 4A | ||
Maximum Operating Temperature 55°C | ||
Hazardous Area Certification No | ||
Width 42mm | ||
Number of Head Directions 4 | ||
Length 192mm | ||
Standards/Approvals IEC 60529 | ||
Depth 40mm | ||
- COO (Country of Origin):
- DE
SICK i10 Series Safety Interlock Switch, 1300N Locking Force, IP67 - i10-M0453 Lock
This safety interlock switch provides electromechanical guard locking for industrial safety applications, using a power-to-release electromagnetic lock and requiring an external actuator. It is housed in glass-fibre reinforced thermoplastic and is designed for machine-guard monitoring where cable gland connection and diagnostic wiring to a safety logic unit are required. The device operates in ambient temperatures from -20°C to +55°C and is suitable for environments requiring an IEC 60529-rated interlock.
Features and Benefits:
• 1300N locking force delivers robust restraint for guarded access
• 2 NC safety contacts support monitored door-status reporting
• Power consumption ≤8W reduces overall control-system load
• Solenoid supply 20.4V DC-26.4V DC enables standard DC control integration
• IP67 enclosure rating protects electronics against dust and water
• 2 NC safety contacts support monitored door-status reporting
• Power consumption ≤8W reduces overall control-system load
• Solenoid supply 20.4V DC-26.4V DC enables standard DC control integration
• IP67 enclosure rating protects electronics against dust and water
Applications
• Used with guarded doors on production machinery
• Suitable for access control in automated assembly lines
• Ideal for integration with safety PLC diagnostic circuits
• Used for perimeter protection in material-handling systems
• Suitable for environments requiring multi-directional actuation
• Suitable for access control in automated assembly lines
• Ideal for integration with safety PLC diagnostic circuits
• Used for perimeter protection in material-handling systems
• Suitable for environments requiring multi-directional actuation
What connection method is provided for wiring?
It uses three M20 cable-gland entries and accepts conductors 0.34mm² to 1.5mm².
How are safety faults detected if the switch has no internal diagnostics?
Fault recognition is performed by the connected safety-related logic unit, which monitors contact states.
What switching performance can be expected for electromotive parts?
Mechanical life is rated at 1 x 10⁶ switching cycles with a B10d parameter of 3 x 10⁶ switching cycles for small loads.
Which voltages and currents are the contacts rated for?
Contacts are specified at 4A for both 230V AC and 24V DC with rated insulation voltage Ui 250V and Uimp 2,500V.
Can the device be actuated from multiple directions?
Yes, it permits actuation from four directions and supports approach speeds up to 20m/min.
相關連結
- SICK i10 Safety Interlock Switch Fibreglass Reinforced Thermoplastic, Electromagnetic
- SICK i10 Safety Interlock Switch Fibreglass Reinforced Thermoplastic, Electromagnetic
- SICK i110 Safety Interlock Switch Fibreglass Reinforced Thermoplastic, Electromagnetic
- SICK i10 Safety Interlock Switch, Fibreglass Reinforced Thermoplastic
- SICK i10 Safety Switch Fibreglass Reinforced Thermoplastic
- SICK i14 Safety Interlock Switch Fibreglass Reinforced Thermoplastic, Electromagnetic
- SICK i14 Safety Switch Fibreglass Reinforced Thermoplastic, Electromagnetic
- SICK i10 Safety Switch Fibreglass Reinforced Thermoplastic, Power to Release