SICK i10 Safety Switch, Power, Fibreglass Reinforced Thermoplastic, Power to Release

小計(1 件)*

TWD11,564.00

(不含稅)

TWD12,142.20

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 1 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD11,564.00

* 參考價格

RS庫存編號:
285-1815
製造零件編號:
i10-M0253 Lock
製造商:
SICK
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SICK

Lock Style

Power

Product Type

Safety Switch

Lock Type

Power to Release

Actuator Included

No

Safety Contacts

2 NC, 2 NO, 1 NC

Housing Material

Fibreglass Reinforced Thermoplastic

Series

i10

Contact AC Voltage

230V ac

Contact DC Voltage

24V dc

Minimum Operating Temperature

-20°C

IP Rating

IP67

Switch Contact Current

4A

Hazardous Area Certification

No

Maximum Operating Temperature

55°C

Standards/Approvals

IEC 60529

Width

42mm

Depth

30mm

Number of Head Directions

4

Length

192mm

COO (Country of Origin):
DE

SICK i10 Series Safety Switch, 1300N Locking Force, Power-to-Release Locking Principle - i10-M0253 Lock


This safety switch is a power-to-release interlock designed to secure access points in industrial environments. It uses electro-mechanical sensing with positive-action contacts to monitor both locking and door status. The unit is suitable for applications requiring sealed protection and defined ambient operating limits, and it is supplied without an actuator.

Features and Benefits:


• IP67 enclosure rating protects equipment from dust and water ingress
• 1300N locking force provides secure retention under load
• 4A switching current supports 230V AC and 24V DC loads
• Power consumption ≤8W reduces control-circuit demand
• Low coding level simplifies actuator matching for Basic systems

Applications


• Suitable for guarding on factory production lines
• Used with safety logic units for monitored interlocks
• Ideal for hygiene-sensitive environments requiring washdown protection
• Can be used for machine access doors with restricted speed
• Used for retrofit safety upgrades on existing guards

What electrical connections does the device require?


It accepts conductors 0.34mm² to 1.5mm² via three M20 cable glands.

How is fault detection achieved in the system?


The unit has no internal fault detection

the connected safety-related logic unit performs diagnostics.

What environmental temperature range can it operate within?


It is rated for operation and storage between -20°C and +55°C.

Which contact configuration is provided for safety monitoring?


The switch offers two positive-action NC contacts for locking monitoring and one NO contact for door monitoring.

What electromagnetic supply is required for the solenoid?


The solenoid operates from 20.4V DC to 26.4V DC.