SICK I15 Safety Switch, Power, Fibreglass Reinforced Thermoplastic

小計(1 件)*

TWD12,176.00

(不含稅)

TWD12,784.80

(含稅)

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2027年1月15日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD12,176.00

* 參考價格

RS庫存編號:
285-1833
製造零件編號:
i15-EP0133 Lock
製造商:
SICK
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SICK

Lock Style

Power

Product Type

Safety Switch

Actuator Included

No

Safety Contacts

1 NC

Housing Material

Fibreglass Reinforced Thermoplastic

Series

I15

Minimum Operating Temperature

-20°C

Contact AC Voltage

230V ac

Contact DC Voltage

24V dc

IP Rating

IP67

Switch Contact Current

1mA

Hazardous Area Certification

No

Maximum Operating Temperature

55°C

Number of Head Directions

4

Length

96mm

Standards/Approvals

CE

Width

42mm

Depth

37.5mm

COO (Country of Origin):
DE

SICK I15 Series Safety Switch, IP67, Fibreglass Reinforced Thermoplastic Housing - i15-EP0133 Lock


This safety switch is an electro-mechanical interlock designed to secure access to machinery and hazardous zones. It uses a power-to-lock mechanism and is intended for industrial installations where a compact, sealed switching device is required. The unit operates within a defined ambient range and connects via a single M20 cable gland, with the actuator supplied separately.

Features and Benefits:


• Power-to-lock mechanism provides secure retention up to 1000N
• 1 NC safety contact enables monitoring with low current loads
• Solenoid supply operates at 20.4 VDC-26.4 VDC for controlled locking
• IP67 enclosure protects against dust ingress and temporary immersion
• Suitable for frequent actuation up to 7000 cycles per hour

Applications


• Suitable for safeguarding access to production machinery
• Used with guarded doors requiring monitored locking
• Ideal for systems requiring Compact safety interlocks
• Can be used in wet or dusty industrial environments

What type of electrical outputs does it provide?


It provides electro-mechanical contacts with slow-action switching elements and supports AC-15/DC-13 usage categories.

How should the unit be wired into a safety circuit?


Individual wiring with diagnostics is required

fault detection is handled by the connected safety logic unit.

What are the environmental operating limits for the device?


It functions between -20°C and +55°C and can be stored within the same temperature range.

Is an actuator included with delivery?


No, the actuator is not supplied and must be ordered separately.

What mechanical forces are relevant to installation?


The device requires an actuation force of at least 35N and resists forces of up to 30N

locking forces of 1000N and 700N apply to specific standards.