SICK i10 Safety Interlock Switch, Fibreglass Reinforced Thermoplastic

小計(1 件)*

TWD1,946.00

(不含稅)

TWD2,043.30

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 17 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD1,946.00

* 參考價格

RS庫存編號:
285-9566
製造零件編號:
i10-PA213
製造商:
SICK
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SICK

Product Type

Safety Interlock Switch

Actuator Included

No

Housing Material

Fibreglass Reinforced Thermoplastic

Series

i10

Contact AC Voltage

240V ac

Switch Contact Current

3A

Minimum Operating Temperature

-25°C

Contact DC Voltage

24V dc

IP Rating

IP66

Hazardous Area Certification

No

Maximum Operating Temperature

80°C

Depth

28mm

Standards/Approvals

IEC 60529

Width

31mm

Length

90mm

Number of Head Directions

4

COO (Country of Origin):
TW

SICK i10 Series Safety Interlock Switch, 3A Rated Current, IP66 - i10-PA213


This safety interlock switch is an electromechanical device designed to monitor access points and safeguard machinery in industrial environments. It provides mechanical actuation with positive-action contacts and is intended for use where robust enclosure protection and predictable switching behaviour are required. The unit connects via an M20 cable gland and is compatible with safety logic systems that perform fault detection.

Features and Benefits:


• 3A current rating provides switching for AC240V and DC24V applications
• IP66 enclosure protects against dust ingress and powerful water jets
• Glass-fibre reinforced thermoplastic housing resists mechanical wear
• Four-direction actuator allows flexible actuation alignment
• Positive-action N/C contacts ensure defined breaking behaviour

Applications


• Suitable for safety guards on production machinery
• Ideal for conveyor access point monitoring
• Used with safety controllers for monitored switching
• Appropriate for enclosed washdown areas requiring high ingress protection

What type of electrical switching does it use?


It uses slow-action switching elements with two positive-action N/C contacts and one N/O contact.

How should faults be detected and handled?


Fault detection must be performed by the connected safety-rated logic unit because the switch has no internal fault monitoring.

What environmental temperatures can it withstand?


It is rated for ambient operation and storage between -25°C and +80°C.

What mechanical durability can be expected?


The device has a mechanical life rated at 10x10^6 switching cycles with small loads.