Fluke I30S Current Clamp, 20 A DC Max, AC/DC Adapter, 20 A AC Max, Voltage Output
- RS庫存編號:
- 645-1836
- Distrelec 貨號:
- 176-12-682
- 製造零件編號:
- I30S
- 製造商:
- Fluke
小計(1 件)*
TWD31,888.00
(不含稅)
TWD33,482.40
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 8 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD31,888.00 |
* 參考價格
- RS庫存編號:
- 645-1836
- Distrelec 貨號:
- 176-12-682
- 製造零件編號:
- I30S
- 製造商:
- Fluke
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Fluke | |
| Adapter Type | AC/DC | |
| Product Type | Current Clamp | |
| Maximum DC Current | 20A | |
| Maximum AC Current | 20A | |
| Accuracy | ±1% + 2 mA | |
| Maximum Conductor Size | 19mm | |
| Output Type | Voltage | |
| Cable Length | 2m | |
| Connector Type | BNC | |
| Battery Type | Alkaline | |
| Battery Life | 30h | |
| Minimum Operating Temperature | 0°C | |
| Maximum Operating Temperature | 50°C | |
| Standards/Approvals | IEC 61326-1 | |
| Model Number | I30S | |
| Safety Category Voltage | 300V | |
| Safety Category Level | CAT III | |
| 選取全部 | ||
|---|---|---|
品牌 Fluke | ||
Adapter Type AC/DC | ||
Product Type Current Clamp | ||
Maximum DC Current 20A | ||
Maximum AC Current 20A | ||
Accuracy ±1% + 2 mA | ||
Maximum Conductor Size 19mm | ||
Output Type Voltage | ||
Cable Length 2m | ||
Connector Type BNC | ||
Battery Type Alkaline | ||
Battery Life 30h | ||
Minimum Operating Temperature 0°C | ||
Maximum Operating Temperature 50°C | ||
Standards/Approvals IEC 61326-1 | ||
Model Number I30S | ||
Safety Category Voltage 300V | ||
Safety Category Level CAT III | ||
豁免
- COO (Country of Origin):
- CN
Fluke Current Clamp, 30A Maximum DC Current, 20A Maximum AC Current - I30S
This current clamp measures both AC and DC currents using Hall-effect sensing for non-intrusive recordings with oscilloscopes and similar instruments, and is designed for field and bench use where isolation from the conductor is required.
Features and Benefits:
• 30mA-30A DC range delivers wide measurement capability for varied loads
• 30mA-20A AC rms range supports common mains and control circuits
• Output sensitivity 100mV/A provides direct voltage output to instruments
• Accuracy ±1% of reading ±2mA ensures precise measurement at 25°C
• Frequency response DC-100kHz enables high-frequency waveform capture
• 2m cable and safety BNC connector allow secure oscilloscope connections
• 30mA-20A AC rms range supports common mains and control circuits
• Output sensitivity 100mV/A provides direct voltage output to instruments
• Accuracy ±1% of reading ±2mA ensures precise measurement at 25°C
• Frequency response DC-100kHz enables high-frequency waveform capture
• 2m cable and safety BNC connector allow secure oscilloscope connections
Applications
• Suitable for waveform capture with oscilloscopes and recorders
• Used for troubleshooting DC motor and drive current anomalies
• Ideal for verifying control circuit currents up to 30A
• Can be used for high-frequency signal monitoring in power electronics
• Used with test instruments requiring voltage-output current probes
• Used for troubleshooting DC motor and drive current anomalies
• Ideal for verifying control circuit currents up to 30A
• Can be used for high-frequency signal monitoring in power electronics
• Used with test instruments requiring voltage-output current probes
What power source does it require and how long does it last?
It uses a 9V alkaline IEC6LR61 battery and provides approximately 30 hours of operation with a low-battery indicator.
What conductor size will it accept?
The clamp opens to accommodate conductors up to 19mm diameter.
Which safety and electromagnetic standards apply to its use?
It meets IEC 61326-1 for EMC and is rated to CAT III 300V for working voltage limits.
How is output zero adjusted for baseline correction?
A manual thumbwheel on the body allows the user to zero the output prior to measurement.
What loading conditions should the measuring instrument present?
The output expects a load impedance greater than 100kΩ and less than or equal to 100pF.
Warning
Use of the probe on uninsulated conductors is limited to 300 V ac rms or dc and frequencies below 1 kHz.
Supplied with
Alkaline PP3 battery, 4mm shrouded plug adaptor and operators manual.
相關連結
- Fluke I310S Current Clamp AC/DC Adapter Voltage Output
- Fluke I30 Current Clamp AC/DC Adapter Current Output
- Fluke 80i-110s Current Clamp BNC Adapter Adapter, 100 A AC Max
- Fluke I410 Current Clamp AC/DC Adapter Voltage Output
- Fluke I1010 Current Clamp AC/DC Adapter Voltage Output
- Fluke I800 Current Clamp 800 A AC Max, Current Output
- Fluke i400 Current Clamp 400 A AC Max, Current Output
- Fluke I200S Current Clamp 240 A AC Max, Voltage Output