Fluke I1010 Current Clamp, 1000 A DC Max, AC/DC Adapter, 600 A AC Max, Voltage Output

小計(1 件)*

TWD22,134.00

(不含稅)

TWD23,240.70

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 5 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD22,134.00

* 參考價格

RS庫存編號:
237-4224
Distrelec 貨號:
176-12-781
製造零件編號:
1640971
製造商:
Fluke
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Fluke

Adapter Type

AC/DC

Product Type

Current Clamp

Maximum DC Current

1000A

Maximum AC Current

600A

Accuracy

±2 % + 0.5 A

Maximum Conductor Size

30mm

Output Type

Voltage

Cable Length

1.6m

Connector Type

4 mm Plug

Battery Life

60h

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

50°C

Standards/Approvals

No

Model Number

I1010

Safety Category Voltage

600V

Safety Category Level

CAT III

豁免

COO (Country of Origin):
TH

Fluke Current Clamp, 600A Maximum AC Current, 1000A Maximum DC Current - 1640971


This current clamp is a portable Hall-effect probe designed to extend multimeter current ranges for both AC and DC measurements in industrial and laboratory settings. It enables non-intrusive measurement of high currents up to 1000A DC and 600A AC while operating from a battery source and delivering a voltage output compatible with standard test instruments.

Features & Benefits


• Measures up to 1000A DC for high-current diagnostics
• Handles 600A AC for alternating-current assessments
• Basic accuracy ±2% + 0.5A for dependable readings
• Output level 1 mV/A for direct multimeter input
• Zero error adjustment to remove offset before measurement
• Battery operation delivers 60 h for extended field use

**Applications**


• Suitable for load testing of large DC supply banks
• Ideal for commissioning motor drives with high inrush currents
• Used with multimetres for fault finding in distribution panels
• Can be used for monitoring current in control cabinets
• Used for maintenance checks on industrial automation equipment

What connector type is provided to link the probe to instruments?


The probe terminates in shrouded 4mm plugs to Interface with standard multimeter inputs.

How large a conductor will the jaw accept for measurement?


The jaw accommodates conductors up to 30mm diameter to fit multiple cable sizes.

What temperature range can it be used within on site?


It operates between -10°C to 50°C, covering most indoor industrial environments.

What is the usable frequency range for AC measurements?


The device measures from DC up to 10 kHz, allowing both mains and higher-frequency signals to be assessed.

What safety classification should technicians note when using it?


It is rated to CAT III 600V for application within building electrical installations.