SICK i200 Safety Interlock Switch, Power, Vistal

小計(1 件)*

TWD12,888.00

(不含稅)

TWD13,532.40

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 3 件準備從其他地點送貨
  • 加上 2 件從 2027年1月13日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD12,888.00

* 參考價格

RS庫存編號:
285-9591
Distrelec 貨號:
303-74-014
製造零件編號:
i200-E0323 Lock
製造商:
SICK
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SICK

Product Type

Safety Interlock Switch

Lock Style

Power

Actuator Included

No

Safety Contacts

1 NC, 2 NC, 1 NO, NC

Housing Material

Vistal

Series

i200

Switch Contact Current

3A

Contact AC Voltage

240V ac

Minimum Operating Temperature

-20°C

IP Rating

IP65

Contact DC Voltage

24V dc

Maximum Operating Temperature

60°C

Hazardous Area Certification

No

Standards/Approvals

CE

Width

93mm

Number of Head Directions

3

Length

126mm

COO (Country of Origin):
DO

SICK i200 Series Safety Interlock Switch, IP65, Power-to-Lock Principle - i200-E0323 Lock


This safety interlock switch is a power-operated locking device designed to secure guards and access points in industrial settings. It uses electro-mechanical sensing and requires an external actuator for operation. The unit is intended for individual wiring with diagnostic capability and is suitable where a compact, sealed interlock with positive-action monitoring contacts is needed.

Features and Benefits:


• 2600N locking force provides secure holding under EN ISO 14119
• 3A rated contacts support 240V AC or 24V DC operation
• IP65 enclosure permits use in dust- and water-exposed areas
• Three actuation directions allow flexible mounting orientations
• Power-to-lock design permits controlled retention during operation

Applications


• Suitable for safeguarding machine access panels in factories
• Ideal for cell door locking with safety-logic integration
• Used with safety controls requiring positive-action contacts
• Can be used for conveyor guard locking where sealing is required
• Suitable for environments needing actuator-sensor separation

What electrical supply is required for the solenoid?


The solenoid requires a 20.4V DC to 26.4V DC supply.

How are field connections implemented?


Connections are via three M20 cable glands accepting 0.34mm² to 1.5mm² conductors.

What diagnostic or fault behaviour is expected?


The switch has no internal fault detection, so the connected safety logic must perform fault monitoring.

What are the specified operating temperature limits?


Ambient operation and storage are rated between -20°C and +60°C.

Is an actuator included with delivery?


The actuator is not supplied with the device.

相關連結

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。