Fluke 287 Digital Digital Multimeter True RMS
- RS庫存編號:
- 156-724
- Distrelec 貨號:
- 176-09-210
- 製造零件編號:
- FLUKE 287/EUR
- 製造商:
- Fluke
小計(1 件)*
TWD35,905.00
(不含稅)
TWD37,700.25
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 30 件準備從其他地點送貨
- 加上 2 件從 2026年5月14日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD35,905.00 |
* 參考價格
- RS庫存編號:
- 156-724
- Distrelec 貨號:
- 176-09-210
- 製造零件編號:
- FLUKE 287/EUR
- 製造商:
- Fluke
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Fluke | |
| Multimeter Type | Digital | |
| Product Type | Multimeter | |
| Display Type | Digital | |
| Model Number | 287 | |
| Functions Measured | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | |
| Maximum DC Voltage Measurement | 1kV dc | |
| True RMS | Yes | |
| DC Current Accuracy | ± 0.05 % | |
| AC Current Accuracy | ± 0.6 % | |
| DC Voltage Accuracy | ±0.025 % | |
| AC Voltage Accuracy | ± 0.4 % | |
| DC Voltage Resolution | 1 μV dc | |
| Maximum Frequency | 100kHz | |
| Resistance Measurement Accuracy | ±0.05 % rdg | |
| Minimum Operating Temperature | -20°C | |
| Battery Life | 200h | |
| Maximum Operating Temperature | 55°C | |
| Weight | 870.9g | |
| Height | 222mm | |
| Length | 60mm | |
| Standards/Approvals | No | |
| Width | 102mm | |
| Safety Category Level | CAT III, CAT IV | |
| Safety Category Voltage | 1000V | |
| Battery Type | AA x 6 | |
| 選取全部 | ||
|---|---|---|
品牌 Fluke | ||
Multimeter Type Digital | ||
Product Type Multimeter | ||
Display Type Digital | ||
Model Number 287 | ||
Functions Measured AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | ||
Maximum DC Voltage Measurement 1kV dc | ||
True RMS Yes | ||
DC Current Accuracy ± 0.05 % | ||
AC Current Accuracy ± 0.6 % | ||
DC Voltage Accuracy ±0.025 % | ||
AC Voltage Accuracy ± 0.4 % | ||
DC Voltage Resolution 1 μV dc | ||
Maximum Frequency 100kHz | ||
Resistance Measurement Accuracy ±0.05 % rdg | ||
Minimum Operating Temperature -20°C | ||
Battery Life 200h | ||
Maximum Operating Temperature 55°C | ||
Weight 870.9g | ||
Height 222mm | ||
Length 60mm | ||
Standards/Approvals No | ||
Width 102mm | ||
Safety Category Level CAT III, CAT IV | ||
Safety Category Voltage 1000V | ||
Battery Type AA x 6 | ||
豁免
- COO (Country of Origin):
- US
Fluke Multimeter, 0.025% DC Voltage Accuracy, 100kHz Maximum Frequency - FLUKE 287/EUR
This multimeter is a handheld, True RMS logging instrument designed for electronic and electrical measurement and analysis in industrial environments. It captures and graphically presents logged readings on a built-in display, enabling on-site trend inspection without a PC. The unit supports voltage, current, resistance, capacitance, frequency and temperature measurements and is suitable for extended field use with battery operation.
Features & Benefits
• True RMS measurement for accurate readings on non-linear loads
• 100kHz AC bandwidth to capture high-frequency signals
• 0.025% Basic DC accuracy for precision DC voltage assessment
• 10A continuous input with 20A for 30s to handle inrush currents
• Logging memory up to 15,000 events for unattended monitoring
• 50,000-count display with zoomable trend view for Rapid analysis
• 100kHz AC bandwidth to capture high-frequency signals
• 0.025% Basic DC accuracy for precision DC voltage assessment
• 10A continuous input with 20A for 30s to handle inrush currents
• Logging memory up to 15,000 events for unattended monitoring
• 50,000-count display with zoomable trend view for Rapid analysis
**Applications**
• Suitable for automation system signal verification and logging
• Ideal for electronics design validation and component testing
• Used for electrical distribution fault-finding and load analysis
• Can be used for temperature profiling of processes and equipment
• Used with power quality assessments up to 100kHz bandwidth
• Ideal for electronics design validation and component testing
• Used for electrical distribution fault-finding and load analysis
• Can be used for temperature profiling of processes and equipment
• Used with power quality assessments up to 100kHz bandwidth
How are recorded readings time-referenced for later review?
Logged entries include a real-time clock timestamp so each measurement can be correlated to clock time for event analysis.
What power source and endurance can I expect during field logging?
The instrument runs on six AA cells and achieves extended battery life of up to 200 hours in logging mode.
How does the device capture fast transients?
It features Peak capture with a 250 μs response to Record short-duration spikes and transients.
Can I remove test lead influence from low-resistance checks?
Yes, a relative mode allows subtraction of test lead resistance to improve low-ohm and capacitance readings.
Supplied with
It comes complete with test leads and alligator clips, so you're set up to tackle most applications.
相關連結
- Fluke 289 Handheld Digital Multimeter True RMS
- Fluke 114 Handheld Digital Multimeter True RMS
- Fluke 115 Handheld Digital Multimeter True RMS
- Fluke 175 Handheld Digital Multimeter True RMS
- Fluke 177 Handheld Digital Multimeter True RMS
- Fluke 28 Handheld Digital Multimeter True RMS
- Fluke 87V-MAX Handheld Digital Multimeter True RMS
- Fluke 83 Handheld Digital Multimeter True RMS