Fluke 117 Fluke 117 Handheld Multimeter True RMS, 10 A ac, 10 A dc, 600 V ac
- RS庫存編號:
- 616-1460
- Distrelec 貨號:
- 176-05-447
- 製造零件編號:
- FLUKE 117 EUR
- 製造商:
- Fluke
小計(1 件)*
TWD12,844.00
(不含稅)
TWD13,486.20
(含稅)
訂單超過 $1,300.00 免費送貨
- 4 件準備發貨
- 加上 140 件準備從其他倉庫發貨
- 加上 1 件從 2026年11月16日 起發貨
單位 | 每單位 |
|---|---|
| 1 - 4 | TWD12,844.00 |
| 5 + | TWD12,587.00 |
* 參考價格
- RS庫存編號:
- 616-1460
- Distrelec 貨號:
- 176-05-447
- 製造零件編號:
- FLUKE 117 EUR
- 製造商:
- Fluke
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Fluke | |
| Multimeter Type | Handheld | |
| Product Type | Multimeter | |
| Model Number | 117 | |
| Display Type | LCD | |
| Resistance Resolution | 100mΩ | |
| Functions Measured | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode Test, Frequency, Resistance | |
| Maximum Resistance Measurement | 6000kΩ | |
| Maximum AC Voltage Measurement | 600V ac | |
| Maximum DC Voltage Measurement | 600V dc | |
| Maximum AC Current Measurement | 10A ac | |
| Maximum DC Current Measurement | 10A dc | |
| True RMS | Yes | |
| AC Current Accuracy | ±1.5 % rdg + 3 Digits | |
| DC Voltage Accuracy | ±0.5 % rdg + 2 Digits | |
| DC Current Accuracy | ±1 % rdg + 3 Digits | |
| AC Voltage Accuracy | ±1 % rdg + 3 Digits | |
| AC Current Resolution | 0.001A ac | |
| AC Voltage Resolution | 0.1mV ac | |
| DC Current Resolution | 0.001A ac | |
| DC Voltage Resolution | 0.1 mV dc | |
| Maximum Frequency | 1kHz | |
| Power Source | Battery | |
| Resistance Measurement Accuracy | 5% + 2 | |
| Minimum Operating Temperature | -10°C | |
| Battery Life | 400h | |
| Maximum Operating Temperature | 50°C | |
| Series | Fluke 117 | |
| Height | 46mm | |
| Length | 167mm | |
| Width | 84mm | |
| Standards/Approvals | CE, N10140, TUV, CSAus, UL, VDE | |
| Weight | 550g | |
| Safety Category Level | CAT III | |
| Safety Category Voltage | 600V | |
| Battery Type | Alkaline | |
| 選取全部 | ||
|---|---|---|
品牌 Fluke | ||
Multimeter Type Handheld | ||
Product Type Multimeter | ||
Model Number 117 | ||
Display Type LCD | ||
Resistance Resolution 100mΩ | ||
Functions Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode Test, Frequency, Resistance | ||
Maximum Resistance Measurement 6000kΩ | ||
Maximum AC Voltage Measurement 600V ac | ||
Maximum DC Voltage Measurement 600V dc | ||
Maximum AC Current Measurement 10A ac | ||
Maximum DC Current Measurement 10A dc | ||
True RMS Yes | ||
AC Current Accuracy ±1.5 % rdg + 3 Digits | ||
DC Voltage Accuracy ±0.5 % rdg + 2 Digits | ||
DC Current Accuracy ±1 % rdg + 3 Digits | ||
AC Voltage Accuracy ±1 % rdg + 3 Digits | ||
AC Current Resolution 0.001A ac | ||
AC Voltage Resolution 0.1mV ac | ||
DC Current Resolution 0.001A ac | ||
DC Voltage Resolution 0.1 mV dc | ||
Maximum Frequency 1kHz | ||
Power Source Battery | ||
Resistance Measurement Accuracy 5% + 2 | ||
Minimum Operating Temperature -10°C | ||
Battery Life 400h | ||
Maximum Operating Temperature 50°C | ||
Series Fluke 117 | ||
Height 46mm | ||
Length 167mm | ||
Width 84mm | ||
Standards/Approvals CE, N10140, TUV, CSAus, UL, VDE | ||
Weight 550g | ||
Safety Category Level CAT III | ||
Safety Category Voltage 600V | ||
Battery Type Alkaline | ||
豁免
Fluke 117 Series Multimeter, 600V Maximum DC Voltage, 10A Maximum DC Current - FLUKE 117 EUR
Features and Benefits:
• 0.1mV DC resolution enabling high-accuracy voltage assessment
• Measures AC and DC currents up to 10A for circuit load verification
• 600V safety rating for CAT III applications in building installations
• Battery operation with around 400h life for extended field use
• Resistance range to 6000kΩ for component and cable testing
Applications
• Ideal for maintenance teams checking motor current draw
• Used for troubleshooting control circuits with continuity and diode tests
• Can be used for capacitor testing in power-factor assessments
• Used with frequency-sensitive equipment diagnostics up to 50kHz
What safety classification governs use near distribution panels?
What is the maximum frequency it can measure?
How long will it typically operate between battery changes?
What is the highest current measurable for clamp or direct tests?
How fine is the meters resistance and DC current resolution?
Note
Contents
相關連結
- Fluke 114 Handheld Multimeter True RMS, 600 V
- Fluke 287 Handheld Multimeter True RMS 10 A, 1 kV
- Fluke 289 Handheld Multimeter True RMS 10 A, 1 kV
- Fluke 83 Handheld Multimeter True RMS
- Fluke 116 Handheld Digital Multimeter True RMS 600 μA dc, 600 V ac
- Fluke 27 Handheld Multimeter True RMS
- Fluke 113 Fluke 113 Handheld Digital Multimeter True RMS, 600 V ac
- Fluke Fluke 117 117 Digital Multimeter Kit True RMS 10 A dc, 600 V ac