Fluke 115, TLK-225-1 Digital Multimeter Multimeter Kit

小計(1 件)*

TWD14,433.00

(不含稅)

TWD15,154.65

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 加上 504 件從 2026年9月28日 起發貨
  • 加上 126 件從 2026年10月02日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD14,433.00

* 參考價格

RS庫存編號:
918-1883
Distrelec 貨號:
300-47-575
製造零件編號:
FLK-115/TLK-225-1
製造商:
Fluke
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Fluke

Model Number

115, TLK-225-1

Product Type

Multimeter Kit

Application

Electrical, Electronic

Kit Contents

Multimeter and a Set of Leads and Probes

Kit Type

Digital Multimeter

Standards/Approvals

CE, N10140, GS, VDE, TUV, UL, CSAus

豁免

COO (Country of Origin):
MY

Fluke Multimeter Kit, 10A Current, Digital Kit Type - FLK-115/TLK-225-1


This multimeter kit provides a handheld digital measurement solution for electrical and electronic diagnostic tasks, supplied with a set of leads and probes. It is intended for field and workshop use, offering voltage, current and resistance measurements with true-rms capability on selected ranges and protection features suitable for typical low- to medium-voltage installations.

Features and Benefits:


• 600 V DC range provides accurate voltage diagnostics
• 10 A and 6 A ranges enable high-current measurement
• True-rms AC measurement ensures accurate waveform readings
• 6000 count display with bargraph improves measurement visibility
• 40 MΩ resistance range detects high-impedance circuits
• 9999 μF capacitance capability supports large-capacitor testing

Applications


• Suitable for electrical installation commissioning tasks
• Ideal for electronic diagnostics on control boards
• Used with motor and generator maintenance checks
• Can be used for appliance repair and fault finding
• Appropriate for HVAC system electrical measurements

What safety categories and approvals does it meet?


It meets IEC61010-1 Pollution Degree 2 and IEC61010-2-033 CAT III 600V specifications and carries CE, VDE, TUV, UL, GS, N10140 and CSAus approvals.

How does the meter handle overload on the A input?


The A input tolerates 20A for 30 seconds and fitted fuse protection is provided on designated inputs.

What temperature and humidity ranges support reliable operation?


It operates between -10°C and +50°C and tolerates up to 90% humidity at 35°C with reduced limits at higher temperatures.

How precise are resistance and capacitance measurements?


Resistance accuracy is typically 0.9% Plus counts across ranges to 40.00MΩ and capacitance accuracy is around 1.9% on many ranges with wider tolerance above 1000μF.

What display and update characteristics aid Rapid diagnostics?


The instrument uses a 6000-count digital readout updating 4/sec Plus a 33-segment bargraph updating 32/sec for quick trend visibility.

Note

This kit can be bought separately with the Fluke 115 (616-1454) and the SureGrip TLK-225 (726-3649)