Application

Electrical, Thermostat

Kit Contents

Case, Magnetic Meter Hanger, Test Leads, Probe, Multimeter

Kit Type

Digital Multimeter

Standards/Approvals

EN 610101, TUV, CSA, UL

豁免

COO (Country of Origin):
US

Fluke Multimeter Kit, Digital Multimeter, Kit Contents Case, Magnetic Meter Hanger, Test Leads, Probe - FLUKE 179/EDA2


This multimeter kit is a True-rms digital diagnostic tool designed for electrical and thermostat work in industrial and field environments. Supplied as a complete kit, it combines a handheld meter with accessory items to support routine measurement, component checks and system troubleshooting where accurate voltage, current and temperature readings are required.

Features & Benefits


• True-rms AC measurement for accurate readings on non-sinusoidal signals
• DC voltage accuracy down to 0.09% for precise low-voltage checks
• Current ranges to 10.00A with 20A over-range for short-duration tests
• Capacitance up to 9999μF for component and filter verification
• Fast continuity detection with beeper response to 250μs events
• Built-in overmould and probe holders for Durable field handling

Applications


• Suitable for thermostat troubleshooting in HVAC installations
• Ideal for commissioning and maintenance of industrial control panels
• Used for electrical system fault-finding and live measurements
• Can be used for electronic component verification on site
• Suitable for recording frequency and capacitance during diagnostics

What overvoltage protection does it provide for on-site use?


The instrument is rated to 1000V between any Terminal and earth and includes surge protection to 8kV Peak as per IEC requirements.

How is battery replacement managed without service disruption?


A dedicated battery access door allows replacement without removing calibration Seals or opening the case.

Which inputs and fuses protect current measurements?


mA inputs are protected by a 440mA 1000V fast fuse and the A input uses an 11A 1000V fast fuse.

How does the display assist Rapid assessment of fluctuating signals?


A 6000-count digital readout updates 4 times per second alongside a 33-segment bargraph updating 40 times per second for quick trend visualisation.

What environmental limits should operators observe during use?


The meter operates between -10°C and +50°C and is specified for use up to 2000m altitude with defined humidity ranges for accurate performance.