Fluke 726 Multi-Function Calibrator, 24 mA, 30V 200 mm 47 mm 96 mm
- RS庫存編號:
- 226-2766
- Distrelec 貨號:
- 176-50-207
- 製造零件編號:
- FLUKE-726
- 製造商:
- Fluke
小計(1 件)*
TWD280,028.00
(不含稅)
TWD294,029.40
(含稅)
訂單超過 $1,300.00 免費送貨
暫時缺貨
- 從 2026年5月25日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD280,028.00 |
* 參考價格
- RS庫存編號:
- 226-2766
- Distrelec 貨號:
- 176-50-207
- 製造零件編號:
- FLUKE-726
- 製造商:
- Fluke
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Fluke | |
| Product Type | Multi-Function Calibrator | |
| Maximum Voltage Measurement | 30V | |
| Accuracy | 0.01 % | |
| Port Connections | Pressure Module | |
| Maximum Current Measurement | 24mA | |
| Battery Life | 25h | |
| Battery Type | AA Alkaline | |
| Power Source | Battery | |
| Minimum Operating Temperature | -10°C | |
| Maximum Operating Temperature | 55°C | |
| Standards/Approvals | CSA C22.2 No. 1010.1:1992, EN500821:1992, EN55022:1994 Class B | |
| Hazardous Area Certification | No | |
| Weight | 650g | |
| Length | 47mm | |
| Height | 200mm | |
| Model Number | 726 | |
| Resolution | 0.01 mV | |
| 選取全部 | ||
|---|---|---|
品牌 Fluke | ||
Product Type Multi-Function Calibrator | ||
Maximum Voltage Measurement 30V | ||
Accuracy 0.01 % | ||
Port Connections Pressure Module | ||
Maximum Current Measurement 24mA | ||
Battery Life 25h | ||
Battery Type AA Alkaline | ||
Power Source Battery | ||
Minimum Operating Temperature -10°C | ||
Maximum Operating Temperature 55°C | ||
Standards/Approvals CSA C22.2 No. 1010.1:1992, EN500821:1992, EN55022:1994 Class B | ||
Hazardous Area Certification No | ||
Weight 650g | ||
Length 47mm | ||
Height 200mm | ||
Model Number 726 | ||
Resolution 0.01 mV | ||
- COO (Country of Origin):
- CN
Fluke Multi-Function Calibrator, 0.01% Accuracy, 25h Battery Life - FLUKE-726/APAC/EMEA
This multi-function calibrator is a portable, battery-powered tool designed for field and workshop calibration of process instrumentation. It measures and sources electrical and temperature signals, simulates pressure with compatible modules, and performs simultaneous dual-channel operations to support transmitter, sensor and loop testing in industrial automation environments.
Features & Benefits
• 0.01% accuracy for precise measurement and sourcing
• 24.000mA sourcing with simultaneous pressure measurement
• 0.01mV resolution for high-precision voltage work
• AA alkaline battery power with 25h typical runtime
• HART-compatible 250ohm insertion for communicator interfacing
• Frequency source and totaliser modes for flowmeter testing
• 24.000mA sourcing with simultaneous pressure measurement
• 0.01mV resolution for high-precision voltage work
• AA alkaline battery power with 25h typical runtime
• HART-compatible 250ohm insertion for communicator interfacing
• Frequency source and totaliser modes for flowmeter testing
Applications
• Suitable for calibrating transmitters and field sensors in process plants
• Ideal for valve and I/P tests requiring simultaneous mA and pressure data
• Used with pressure modules to validate pressure transmitters and switches
• Can be used to verify RTDs and thermocouples on temperature loops
• Suitable for loop power and signal verification on control panels
• Ideal for valve and I/P tests requiring simultaneous mA and pressure data
• Used with pressure modules to validate pressure transmitters and switches
• Can be used to verify RTDs and thermocouples on temperature loops
• Suitable for loop power and signal verification on control panels
What pressure capability exists with the unit?
Pressure functions require one of the specified pressure modules and a pump
the instrument accepts Fluke 700Pxx modules for measurement and sourcing when connected.
How does it support HART instrumentation?
It inserts a 250ohm resistor in the mA measure and source paths to provide correct signalling impedance for HART devices.
Which signal types can be sourced and measured simultaneously?
Two independent channels allow concurrent measure, source or simulation of volts, mA, RTDs, thermocouples, resistance and frequency, enabling tasks such as sourcing mA while logging pressure.
What environmental limits affect field use?
The unit operates from -10°C to 55°C and survives storage from -20°C to 71°C, with defined humidity performance across its operating range.
What input protection and certifications are present?
The design includes enhanced voltage input protection and meets CSA C22.2 No.1010.1 and EN/EMC standards EN50082-1 and EN55022 Class B.
Note
This Multi Function Calibrator is shipped with a NIST Calibration certificate.
相關連結
- Fluke 725 Multi-Function Calibrator 30V 236 mm 130 mm 47 mm
- Fluke 789 Multi-Function Calibrator 1000V ac 50 mm 203 mm 100 mm
- Time Electronics 1017 Multi-Function Calibrator 100V 119 mm 47 mm 96 mm
- Fluke 789FC Multi-Function Calibrator 1000V 50 mm 100 mm 203 mm
- Druck Genii IS Multi-Function Calibrator 30V 183 mm 96 mm 200 mm
- Fluke Fluke-712B Temperature Calibrator
- Keysight Technologies N9311X Multi-Function Calibrator
- Time Electronics 1021 Multi-Function Calibrator