Fluke 725 Multi-Function Calibrator, 24 mA, 30V 236 mm 130 mm 61mm

小計(1 件)*

TWD221,822.00

(不含稅)

TWD232,913.10

(含稅)

Add to Basket
選擇或輸入數量
庫存資訊目前無法存取 - 請稍後再回來查看
單位
每單位
1 +TWD221,822.00

* 參考價格

RS庫存編號:
231-3002
Distrelec 貨號:
176-50-203
製造零件編號:
725/APAC/EMEA
製造商:
Fluke
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Fluke

Maximum Voltage Measurement

30V

Product Type

Multi-Function Calibrator

Accuracy

± 0.02 % + 2 LSD

Port Connections

HART, Pressure Module

Battery Life

25h

Maximum Current Measurement

24mA

Battery Type

AA Alkaline

Power Source

Battery

Safety Category Voltage

30V

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

55°C

Length

130mm

Width

61mm

Standards/Approvals

EN50082-1:1992 and EN55022:1994 Class B

Weight

650g

Hazardous Area Certification

No

Height

236mm

Model Number

725

Resolution

0.1 °C

COO (Country of Origin):
CN

Fluke Multi-Function Calibrator, 0.02% Accuracy, 25h Battery Life - 725/APAC/EMEA


This multi-function calibrator is a handheld tool for measuring and sourcing process signals in industrial control and instrumentation work. It supports simultaneous dual-channel operation to test sensors and transmitters, provides loop power for transmitter checks and permits pressure measurement when used with compatible pressure modules. The instrument is battery-powered for field use across common automation and electrical environments.

Features & Benefits


• 0.02% accuracy with 2 least-significant-digit tolerance delivers precise calibrations
• 24.000 mA sourcing with simultaneous loop measurement enables valve and I/P testing
• 24V loop supply powers transmitters during in-situ checks
• HART compatibility through 250 Ω insertion supports HART instrument interaction
• Battery operation on AA cells yields 25 h typical runtime for extended field shifts
• 30V safety category rating aligns with EN55022 electromagnetic standards

**Applications**


• Suitable for calibrating current loops and transducers in control panels
• Ideal for commissioning and troubleshooting transmitters with pressure modules
• Used for temperature sensor verification with thermocouple and RTD simulation
• Can be used for frequency and flowmeter Pulse testing in process lines
• Used with valve benches for simultaneous pressure and mA characterisation

What power options and runtime can I expect in the field?


It runs from four AA alkaline cells and typically operates for 25 h under normal use.

Which pressure capability is available with this instrument?


Pressure measurement or sourcing requires one of the Fluke 700Pxx modular pressure modules and a separate pressure pump.

How does it handle temperature sensor types?


It measures and simulates multiple thermocouple and RTD types with 0.1 °C to 1 °C resolution depending on sensor selection.

What environmental temperatures does it support during operation?


The instrument functions across an ambient range from -10 °C to 55 °C for typical field conditions.

What physical characteristics affect portability on site?


It weighs 650 g and uses battery power, making it a Compact portable loop calibrator for 24 mA tasks.