規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Fluke | |
| Product Type | Test Probe | |
| Current | 2A | |
| Colour | Red, Black | |
| Minimum Operating Temperature | 0°C | |
| Maximum Operating Temperature | 50°C | |
| Standards/Approvals | No | |
| 選取全部 | ||
|---|---|---|
品牌 Fluke | ||
Product Type Test Probe | ||
Current 2A | ||
Colour Red, Black | ||
Minimum Operating Temperature 0°C | ||
Maximum Operating Temperature 50°C | ||
Standards/Approvals No | ||
豁免
- COO (Country of Origin):
- US
Fluke Test Probe, 40kV Voltage, 2A Current - 80K-40
This test probe extends a voltmeters measuring range to very high potentials for low-energy circuits within equipment. It is intended for use where energy is limited, providing compatibility with instruments that have high input impedance and enabling measurements up to the rated Peak voltage in both AC and DC environments.
Features & Benefits
• Measures up to 40 kV Peak while protecting instrument input
• Compatible with 10 MΩ voltmeter inputs for accuracy
• Rated for 2 A carrying capability to match test set-ups
• Specified operating temperature up to 50 °C for warm environments
• Supplied in red and black for clear polarity identification
• Compatible with 10 MΩ voltmeter inputs for accuracy
• Rated for 2 A carrying capability to match test set-ups
• Specified operating temperature up to 50 °C for warm environments
• Supplied in red and black for clear polarity identification
Applications
• Suitable for measuring high voltages inside televisions and copiers
• Ideal for insulation testing on low-energy assemblies
• Used with bench voltmeters for component-level diagnostics
• Can be used for lab-based HV troubleshooting on equipment
• Ideal for insulation testing on low-energy assemblies
• Used with bench voltmeters for component-level diagnostics
• Can be used for lab-based HV troubleshooting on equipment
Can this probe be used on power distribution systems?
No, it is limited to energy-restricted circuits and must not be applied to power distribution measurements.
Which voltmeter input impedance yields best accuracy?
Use with a 10 MΩ input impedance voltmeter to achieve the stated measurement performance.
What environmental temperature range is acceptable for operation?
It operates between 0 °C and 50 °C as per its rated thermal limits.
What polarity identification and lead colours are provided?
The accessory includes red and black leads to distinguish positive and negative connections.
Note