Eaton PFIM RCD, 16A, 2 Pole, 30mA, Type A, 230V ac

小計(1 件)*

TWD5,542.00

(不含稅)

TWD5,819.10

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 3 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD5,542.00

* 參考價格

RS庫存編號:
922-8648
製造零件編號:
235423 PFIM-16/2/003-A-MW
製造商:
Eaton
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Eaton

Circuit Breaker Type

RCD

Current Rating

16A

Number of Poles

2

Range

PFIM

Trip Sensitivity

30mA

Tripping Characteristics

Type A

Voltage Rating

230V ac

Series

PFIM

Standards Met

IEC/EN 61008

Break Time

Instantaneous

Terminal Contact Type

Screw

Overall Depth

80mm

Overall Length

76mm

Earth Leakage Protection Type

A

Mounting Style

DIN Rail Mount

Rated AC Voltage

230, 400V

Overall Width

35mm

Overall Dimensions

35 x 65.5 x 80mm

Breaking Capacity at Maximum Voltage Rating

10 kA

Application

Commercial, Residential

Reset Actuator Type

Toggle Switch

Eaton PFIM Series RCD, 16A Current Rating, 30mA Trip Sensitivity - 235423 PFIM-16/2/003-A-MW


This residual current device (RCD) provides essential earth leakage protection for commercial and residential applications. Designed for mounting on a DIN rail, the device features a robust, compact design measuring 35 x 76 x 80 mm. Compliant with IEC/EN 61008 standards, it effectively trips at a sensitivity of 30mA, ensuring safety without compromising functionality.

Features & Benefits


• Instantaneous break time enhances user safety during faults
• Type A RCD breaker protects against earth leakage currents
• Rated current of 16A suits a variety of electrical installations
• 2-pole configuration allows for versatile circuit applications
• Capable of withstanding breaking capacity of 10kA
• Easily mounted on standard DIN rails for convenience

Applications


• Used for protection in residential electrical systems
• Ideal for commercial installations requiring reliable earth fault protection
• Can be used in functions effectively in various voltage up to 400V

How does the earth leakage protection function in this device?


Earth leakage protection is achieved through a sensitive trip mechanism that detects imbalance between live and neutral currents, tripping the circuit to prevent electric shocks. The 30mA sensitivity provides suitable protection for both residential and commercial environments.

What are the temperature specifications for using this device?


The device is rated for operation in ambient temperatures ranging from -25°C to 55°C, which ensures efficiency in diverse environmental conditions. It's important to note that continuous current capability decreases by 3% for each degree above 40°C.

Can this RCD be integrated with other devices in a switchboard?


Yes, it can be easily integrated with other electrical devices, as it supports selective protection and a range of additional equipment. Proper installation should be followed according to manufacturer guidelines for optimal performance.

Note

Eaton formerly known as Moeller

相關連結