Eaton PFIM RCD, 63A, 4 Pole, 30mA, Type AC, 230V ac
- RS庫存編號:
- 922-8639
- 製造零件編號:
- 235414 PFIM-63/4/003-MW
- 製造商:
- Eaton
單價 個**
TWD8,165.00
(不含稅)
TWD8,573.25
(含稅)
7 現貨庫存,可於6工作日發貨。*
* 交貨日期可能會根據您選擇的數量和交貨地址而變更。
訂單金額滿 TWD2,857.00 (未稅) 即可享受 免費 送貨服務
單位 | 每單位 |
---|---|
1 + | TWD8,165.00 |
** 參考價格
- RS庫存編號:
- 922-8639
- 製造零件編號:
- 235414 PFIM-63/4/003-MW
- 製造商:
- Eaton
- COO (Country of Origin):
- RO
Eaton PFIM Series RCD, 63A Current Rating, 4 Poles - 235414 PFIM-63/4/003-MW
This residual current device (RCD) offers robust protection against earth leakage currents, making it ideal for ensuring safety in both residential and commercial applications. Featuring four poles and a rated current of 63A, this reliable unit ensures effective circuit protection. With dimensions of 70 x 76 x 80 mm, it is compact yet efficient, designed for easy mounting on a DIN rail.
Features & Benefits
• Provides 30mA sensitivity for enhanced safety against electric shocks
• Type AC tripping characteristics for reliable performance
• Instantaneous tripping mechanism for rapid response to faults
• Screw terminal contact type ensures secure and stable connections
• Built to operate in ambient temperatures up to 55°C
• Type AC tripping characteristics for reliable performance
• Instantaneous tripping mechanism for rapid response to faults
• Screw terminal contact type ensures secure and stable connections
• Built to operate in ambient temperatures up to 55°C
Applications
• Utilised for residential circuit protection in domestic installations
• Used for commercial RCD installations requiring safety compliance
• Suitable for environments needing earth leakage protection
• Ideal for smart machinery and automation systems needing reliable circuit safety
• Can be used in electrical distribution boards for enhanced safety
• Used for commercial RCD installations requiring safety compliance
• Suitable for environments needing earth leakage protection
• Ideal for smart machinery and automation systems needing reliable circuit safety
• Can be used in electrical distribution boards for enhanced safety
What safety standards does this device meet?
This device meets the IEC/EN 61008 standard, ensuring reliability and safety in electrical installations.
How does ambient temperature affect its operation?
Operating beyond the specified temperature limits can decrease the permissible continuous current by 3% for each degree over 40°C.
What maintenance is required for optimal performance?
Regular inspection of the device is advised to ensure all connections remain tight and that the tripping mechanism functions properly.
Can the device be used with both single-phase and three-phase systems?
Yes, it is rated for use with AC voltages of 230V and 400V, making it versatile for various electrical setups.
How does this device prevent electrical hazards?
It provides earth leakage protection by tripping the circuit immediately if leakage exceeds 30mA, reducing the risk of electric shock.
Note
Eaton formerly known as Moeller
屬性 | 值 |
---|---|
Circuit Breaker Type | RCD |
Current Rating | 63A |
Number of Poles | 4 |
Range | PFIM |
Trip Sensitivity | 30mA |
Tripping Characteristics | Type AC |
Voltage Rating | 230V ac |
Series | PFIM |
Standards Met | IEC/EN 61008 |
Overall Length | 76mm |
Mounting Style | DIN Rail Mount |
Rated AC Voltage | 230, 400V |
Overall Depth | 80mm |
Overall Width | 70mm |
Terminal Contact Type | Screw |
Break Time | Instantaneous |
Application | Commercial, Residential |
Breaking Capacity at Maximum Voltage Rating | 10 kA |
Overall Dimensions | 70 x 76 x 80mm |
Earth Leakage Protection Type | AC |
Reset Actuator Type | Toggle Switch |