Better World
Siemens Residual Current Circuit Breaker with Overload Protection, 13A Current Rating, 2-Pole, 30 mA Trip Sensitivity,
- RS庫存編號:
- 187-3288
- Distrelec 貨號:
- 301-49-285
- 製造零件編號:
- 5SV1316-7KK13
- 製造商:
- Siemens
小計(1 件)*
TWD5,712.00
(不含稅)
TWD5,997.60
(含稅)
庫存資訊目前無法存取 - 請稍後再回來查看
單位 | 每單位 |
|---|---|
| 1 + | TWD5,712.00 |
* 參考價格
Better World
我們的 Better World 產品系列可讓您輕鬆選擇值得信賴的環保產品。 點擊此處了解更多。
- RS庫存編號:
- 187-3288
- Distrelec 貨號:
- 301-49-285
- 製造零件編號:
- 5SV1316-7KK13
- 製造商:
- Siemens
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Siemens | |
| Current Rating | 13A | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Number of Poles | 2 | |
| Range | SENTRON | |
| Series | 5SV1316 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type C | |
| Mount Type | DIN Rail | |
| Rated AC Voltage | 230V | |
| Terminal Type | Screw | |
| Earth Leakage Protection Type | Type A | |
| Depth | 77mm | |
| Width | 18mm | |
| Height | 90mm | |
| Better World Claim | Concentrated or Compact Solution, Extended Product Life, Low Carbon Manufacture | |
| Better World Product | Yes | |
| Standards/Approvals | No | |
| Breaking Capacity | 6kA | |
| 選取全部 | ||
|---|---|---|
品牌 Siemens | ||
Current Rating 13A | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Number of Poles 2 | ||
Range SENTRON | ||
Series 5SV1316 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type C | ||
Mount Type DIN Rail | ||
Rated AC Voltage 230V | ||
Terminal Type Screw | ||
Earth Leakage Protection Type Type A | ||
Depth 77mm | ||
Width 18mm | ||
Height 90mm | ||
Better World Claim Concentrated or Compact Solution, Extended Product Life, Low Carbon Manufacture | ||
Better World Product Yes | ||
Standards/Approvals No | ||
Breaking Capacity 6kA | ||
- COO (Country of Origin):
- RO
Siemens 5SV1316 Series Residual Current Circuit Breaker with Overload Protection, 13A Current, 30mA Trip Sensitivity - 5SV1316-7KK13
This residual current circuit-breaker with overload protection provides combined earth-fault detection and overcurrent interruption for single-phase installations. Designed for DIN-rail fitting in distribution boards, it protects circuits by disconnecting on residual currents and instantaneous overloads while supporting AC supply systems at 230V and 50 Hz.
Features & Benefits
• Type A detection with 30 mA sensitivity for AC and pulsating faults
• 6 kA breaking capacity to limit fault energy and damage
• Type C instantaneous tripping for moderate inrush current tolerance
• Two-pole design enabling simultaneous live and NEUTRAL switching
• Screw terminals accepting up to 16mm² for robust conductor connections
• Compact width of 18mm conserving panel space
• 6 kA breaking capacity to limit fault energy and damage
• Type C instantaneous tripping for moderate inrush current tolerance
• Two-pole design enabling simultaneous live and NEUTRAL switching
• Screw terminals accepting up to 16mm² for robust conductor connections
• Compact width of 18mm conserving panel space
Applications
• Suitable for residential distribution boards requiring earth-leakage protection
• Ideal for small commercial installations with single-phase circuits
• Used for protecting lighting and socket circuits with moderate inrush currents
• Can be used for retrofit projects where DIN-rail mounting is required
• Ideal for small commercial installations with single-phase circuits
• Used for protecting lighting and socket circuits with moderate inrush currents
• Can be used for retrofit projects where DIN-rail mounting is required
What is the expected mechanical service life under normal switching?
The device is rated for approximately 10,000 switching cycles in typical mechanical operation.
How does ambient temperature affect rated current-carrying capability?
The rated 13A current is derated progressively with temperature, for example to about 12.35A at 40 °C and to about 10.01A at 70 °C.
What installation orientations and clearances are supported?
It may be mounted in any position on a standard DIN rail and offers IP20 protection when installed with conductors connected inside a distribution enclosure.
Which surge and switching performance figures are relevant for coordination?
Surge resistance is about 1 kA for an 8/20 μs waveform and switching capacities include 6 kA per EN 60898 and 15 kA per IEC 60947-2.
What conductor preparations and tightening parameters are required?
Stranded conductors up to 16mm² and finely stranded with ferrules up to 10mm² are acceptable and Terminal screws should be tightened to between 1.2 and 2 N·m.
相關連結
- Siemens Residual Current Circuit Breaker with Overload Protection 2-Pole
- Siemens Residual Current Circuit Breaker with Overload Protection 2-Pole
- Siemens Residual Current Circuit Breaker with Overload Protection 2-Pole
- Siemens Residual Current Circuit Breaker with Overload Protection 1-Pole
- Lovato Residual Current Circuit Breaker with Overload Protection 1-Pole
- Siemens Residual Current Circuit Breaker with Overload Protection 4-Pole
- Siemens Residual Current Circuit Breaker with Overload Protection 3-Pole
- Siemens Residual Current Circuit Breaker with Overload Protection 2-Pole