Better World

Siemens Residual Current Circuit Breaker with Overload Protection, 10A Current Rating, 2-Pole, 30 mA Trip Sensitivity,

小計(1 件)*

TWD5,993.00

(不含稅)

TWD6,292.65

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 31 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD5,993.00

* 參考價格

Better World

我們的 Better World 產品系列可讓您輕鬆選擇值得信賴的環保產品。 點擊此處了解更多。

RS庫存編號:
187-3287
Distrelec 貨號:
301-49-284
製造零件編號:
5SV1316-7KK10
製造商:
Siemens
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Siemens

Current Rating

10A

Product Type

Residual Current Circuit Breaker with Overload Protection

Number of Poles

2

Range

SENTRON

Series

5SV1316

Trip Sensitivity

30mA

Tripping Characteristics

Type C

Mount Type

DIN Rail

Rated AC Voltage

195V ac

Terminal Type

Screw

Earth Leakage Protection Type

Type A

Height

90mm

Depth

77mm

Width

18mm

Better World Product

Yes

Better World Claim

Concentrated or Compact Solution, Extended Product Life, Low Carbon Manufacture

Breaking Capacity

6kA

Standards/Approvals

No

Siemens 5SV1316 Series Residual Current Circuit Breaker with Overload Protection, 10A Current, 30mA Trip Sensitivity - 5SV1316-7KK10


This residual current circuit breaker with overload protection is a Compact protective device designed for single-phase electrical systems. It combines earth-leakage detection with overcurrent protection to interrupt supply during fault conditions, and is intended for DIN-rail mounting in industrial and control-panel installations.

Features & Benefits


• 10A rated current provides defined circuit overload protection
• 30mA trip sensitivity limits dangerous earth-leakage exposure
• 2-pole configuration enables simultaneous live and NEUTRAL disconnection
• 6kA breaking capacity allows safe interruption of short-circuit currents
• Type C tripping characteristic supports moderate inrush loads
• Screw terminals ensure secure conductor clamping at connections

Applications


• Suitable for machinery control panels requiring combined RCD/overload protection
• Ideal for distribution boards in light-industrial installations
• used with automation equipment needing 230V earth-leakage protection
• Can be used for circuits with motors or transformers that have inrush currents

What type of earth-leakage detection does it provide?


It uses Type A earth-leakage sensing with 30mA sensitivity to detect AC and pulsating DC residual currents.

How is it mounted and connected in typical installations?


It is designed for DIN-rail mounting and connects via screw terminals for straightforward panel wiring.

What electrical network voltage is it intended for?


The device is specified for use on 230V AC single-phase systems.

Are there multiple poles and what does that imply for isolation?


It is a 2-pole unit, enabling concurrent isolation of live and NEUTRAL conductors.

相關連結