Fluke FLK-729 300G -0.82 bar to 20.68 bar Pressure Calibrator
- RS庫存編號:
- 144-5554
- 製造零件編號:
- FLK-729 300G
- 製造商:
- Fluke
此圖片僅供參考,請參閲產品詳細資訊及規格
小計(1 件)*
TWD620,356.00
(不含稅)
TWD651,373.80
(含稅)
訂單超過 $1,300.00 免費送貨
有限的庫存
- 1 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD620,356.00 |
* 參考價格
- RS庫存編號:
- 144-5554
- 製造零件編號:
- FLK-729 300G
- 製造商:
- Fluke
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Fluke | |
| Battery Type | Rechargeable | |
| Maximum Pressure Measurement | 20.68bar | |
| Product Type | Pressure Calibrator | |
| Minimum Pressure Measurement | -0.82bar | |
| Accuracy | ±0.01 % | |
| Resolution | -0.8273 → 20.6843 bar | |
| Pressure Port Type | Differential | |
| Model Number | FLK-729 300G | |
| Data Logging | Yes | |
| Current Loop Measurement | Yes | |
| Display Type | LCD | |
| Leak Testing | Yes | |
| Power Source | Battery | |
| Minimum Operating Temperature | -10°C | |
| Weight | 2.95kg | |
| Maximum Operating Temperature | 50°C | |
| Height | 70mm | |
| Length | 172.7mm | |
| Width | 279.4mm | |
| Standards/Approvals | No | |
| Hazardous Area Certification | No | |
| 選取全部 | ||
|---|---|---|
品牌 Fluke | ||
Battery Type Rechargeable | ||
Maximum Pressure Measurement 20.68bar | ||
Product Type Pressure Calibrator | ||
Minimum Pressure Measurement -0.82bar | ||
Accuracy ±0.01 % | ||
Resolution -0.8273 → 20.6843 bar | ||
Pressure Port Type Differential | ||
Model Number FLK-729 300G | ||
Data Logging Yes | ||
Current Loop Measurement Yes | ||
Display Type LCD | ||
Leak Testing Yes | ||
Power Source Battery | ||
Minimum Operating Temperature -10°C | ||
Weight 2.95kg | ||
Maximum Operating Temperature 50°C | ||
Height 70mm | ||
Length 172.7mm | ||
Width 279.4mm | ||
Standards/Approvals No | ||
Hazardous Area Certification No | ||
豁免
- COO (Country of Origin):
- CN
Fluke Pressure Calibrator, ±0.01% Accuracy, 20.68 Bar Maximum Pressure Measurement - FLK-729 300G
This pressure calibrator is a portable, battery-powered instrument designed for pressure generation, control and measurement in process environments. It combines automatic electric pumping with pressure regulation and supports electrical loop functions including mA sourcing, simulation and measurement, enabling field technicians to perform multi-point calibrations and document results efficiently.
Features & Benefits
• Automatic pump to 20.68 bar for set-point attainment and control
• ±0.01% accuracy for precise measurement and calibration results
• 24V loop power for powering and testing transmitters
• Built-in leak testing to verify integrity of test setups
• LCD multi-channel graphical display for clear data visualisation
• Rechargeable battery operation for field portability and autonomy
• ±0.01% accuracy for precise measurement and calibration results
• 24V loop power for powering and testing transmitters
• Built-in leak testing to verify integrity of test setups
• LCD multi-channel graphical display for clear data visualisation
• Rechargeable battery operation for field portability and autonomy
**Applications**
• Suitable for commissioning and calibration of process transmitters
• Ideal for loop current measurement verification on plant skids
• Used for HART transmitter mA trim and light configuration tasks
• Can be used for pressure switch testing with automated sequences
• Used with RTD probes for temperature-related calibration checks
• Ideal for loop current measurement verification on plant skids
• Used for HART transmitter mA trim and light configuration tasks
• Can be used for pressure switch testing with automated sequences
• Used with RTD probes for temperature-related calibration checks
What pressure range can it cover for industrial calibrations?
It can apply and measure from -0.82 to 20.68 bar, accommodating vacuum through high-pressure tasks.
How does it simplify multi-point calibration workflows?
You enter start/end pressures and point count and the device automatically steps, stabilises and logs each test point.
What electrical measurement capabilities does it provide beyond pressure?
It measures, sources and simulates 0–24mA, measures 0–30Vdc and supplies 24V loop power for standalone tests.
How does the instrument handle minor system leaks during a test?
An automatic fine-pressure adjustment feature compensates for small leaks to maintain set-points without manual vernier adjustments.
What environmental operating limits affect pressure control and charging?
Measurement functions operate from -10°C to 50°C while pressure control is rated 0°C to 50°C and the battery will only charge up to 40°C.
相關連結
- Fluke 719P-300G/KIT -0.8 bar to 20 bar Pressure Calibrator
- Fluke 717 -850 mbar to 20 bar Pressure Calibrator
- Fluke 718 -850 mbar to 20 bar Pressure Calibrator
- Fluke 719PRO -0.8 bar to 10 bar Pressure Calibrator
- Fluke 719PRO -0.8 bar to 2 bar Pressure Calibrator
- Fluke 719P-150G/KIT -0.8 bar to 10 bar Pressure Calibrator
- Fluke 719P-30G/KIT -0.8 bar to 2 bar Pressure Calibrator
- TE Connectivity Pressure Sensor, 20.68 bar Operating Max