Fluke 719P-30G/KIT -0.8 bar to 2 bar Pressure Calibrator
- RS庫存編號:
- 458-135
- 製造零件編號:
- FLK-719P-30G/KIT
- 製造商:
- Fluke
小計(1 件)*
TWD189,530.00
(不含稅)
TWD199,006.50
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 3 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD189,530.00 |
* 參考價格
- RS庫存編號:
- 458-135
- 製造零件編號:
- FLK-719P-30G/KIT
- 製造商:
- Fluke
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Fluke | |
| Maximum Pressure Measurement | 2bar | |
| Product Type | Pressure Calibrator | |
| Battery Type | AA Alkaline | |
| Minimum Pressure Measurement | -0.8bar | |
| Accuracy | 0.0001 bar | |
| Resolution | 0.0001 bar | |
| Pressure Port Type | Gauge | |
| Model Number | 719P-30G/KIT | |
| Display Type | Backlight | |
| Current Loop Measurement | Yes | |
| Leak Testing | Yes | |
| Power Source | Battery | |
| Weight | 1.2kg | |
| Minimum Operating Temperature | -10°C | |
| Maximum Operating Temperature | 50°C | |
| Length | 70mm | |
| Height | 241.3mm | |
| Width | 111.8mm | |
| Standards/Approvals | Traceable Certificate of Calibration | |
| Hazardous Area Certification | No | |
| 選取全部 | ||
|---|---|---|
品牌 Fluke | ||
Maximum Pressure Measurement 2bar | ||
Product Type Pressure Calibrator | ||
Battery Type AA Alkaline | ||
Minimum Pressure Measurement -0.8bar | ||
Accuracy 0.0001 bar | ||
Resolution 0.0001 bar | ||
Pressure Port Type Gauge | ||
Model Number 719P-30G/KIT | ||
Display Type Backlight | ||
Current Loop Measurement Yes | ||
Leak Testing Yes | ||
Power Source Battery | ||
Weight 1.2kg | ||
Minimum Operating Temperature -10°C | ||
Maximum Operating Temperature 50°C | ||
Length 70mm | ||
Height 241.3mm | ||
Width 111.8mm | ||
Standards/Approvals Traceable Certificate of Calibration | ||
Hazardous Area Certification No | ||
- COO (Country of Origin):
- US
Fluke Pressure Calibrator, 2bar Maximum Pressure Measurement, 0.0001 Bar Accuracy - FLK-719P-30G/KIT
This pressure calibrator is a portable handheld instrument designed for field calibration and testing of transmitters, switches and gauges, providing both pressure generation and loop calibration functions. It operates from battery power and presents measurements on a large backlit display, allowing users to source, simulate and measure mA signals while also offering temperature measurement capability via an optional RTD probe. The unit supports negative pressure measurement down to -0.8 bar and delivers traceable calibration documentation.
Features and Benefits:
• 0.0001 bar resolution delivers fine pressure adjustment and repeatable results
• 0.0001 bar accuracy supports reference-class transmitter calibration
• Programmemable pump limits prevent over-pressurisation during setup
• Integrated electric pump enables one-handed pressure generation up to 20 bar
• Current loop measurement allows sourcing and measuring of 0-24 mA signals
• Battery powered using AA alkaline cells for field portability
• 0.0001 bar accuracy supports reference-class transmitter calibration
• Programmemable pump limits prevent over-pressurisation during setup
• Integrated electric pump enables one-handed pressure generation up to 20 bar
• Current loop measurement allows sourcing and measuring of 0-24 mA signals
• Battery powered using AA alkaline cells for field portability
Applications
• Suitable for calibrating high-accuracy pressure transmitters on-site
• Used for functional testing of pressure switches in maintenance rounds
• Ideal for pressure gauge verification in plant inspection tasks
• Can be used for leak testing procedures with non-corrosive gases
• Used with optional RTD probe for combined temperature verification
• Used for functional testing of pressure switches in maintenance rounds
• Ideal for pressure gauge verification in plant inspection tasks
• Can be used for leak testing procedures with non-corrosive gases
• Used with optional RTD probe for combined temperature verification
What pressure connection type does it use?
The instrument accepts a 1/8 in female NPT pressure connection for field hoses and adapters.
How does temperature affect accuracy outside standard conditions?
Add ±0.002% of full scale per °C for operation outside 15 °C to 35 °C when assessing measurement uncertainty.
What are the power requirements and expected pump cycles?
It requires eight AA alkaline batteries and provides a minimum of 1000 pump cycles to 30 psi, 300 cycles to 150 psi and 100 cycles to 300 psi depending on range.
Which media are permissible for pressure measurement?
Pressure measurement is limited to dry Air and non-corrosive gases when using the internal sensor.
What electrical measurement limits apply when simulating mA?
The mA source supports a maximum 1000 Ω load and the mA simulate function must not exceed 26 V dc.
相關連結
- Fluke 719P-150G/KIT -0.8 bar to 10 bar Pressure Calibrator
- Fluke 719P-300G/KIT -0.8 bar to 20 bar Pressure Calibrator
- Fluke 719PRO -0.8 bar to 2 bar Pressure Calibrator
- Fluke 719PRO -0.8 bar to 10 bar Pressure Calibrator
- Fluke 717 -850 mbar to 2 bar Pressure Calibrator
- Fluke 719 -850 mbar to 2.4 bar Pressure Calibrator
- Fluke FLK-729 300G -0.82 bar to 20.68 bar Pressure Calibrator
- Fluke 721EX -0.83 bar to 6.9 bar Pressure Calibrator