Norgren Pneumatic Timer 10 bar max

小計(1 件)*

TWD7,597.00

(不含稅)

TWD7,976.85

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 12 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD7,597.00

* 參考價格

RS庫存編號:
777-126
製造零件編號:
04043102000
製造商:
Norgren
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Norgren

Product Type

Pneumatic Timer

Hazardous Area Certification

No

Series

04

Minimum Operating Pressure

2bar

Maximum Operating Pressure

10 bar

Minimum Operating Temperature

-20°C

Maximum Operating Temperature

80°C

Standards/Approvals

No

豁免

COO (Country of Origin):
GB

IMI Norgren Pneumatic Timer, 2 to 10 Bar Operating Pressure Range, 0.2 to 0.4ms Operating Time Range - 04 Series - 04043102000


Ensure you never miss a beat with this pneumatic timer from IMI Norgren. It precisely controls compressed air inputs to boost the effective functioning of your applications and cut time spent on maintenance out of the equation. Prevent trapped signals and the need for resets by nudging the unit between your trip and directional control valves. This keeps outputs at 90% for consistent performance and reliability. The component handles operating pressures between 2 and 10 bar, making it a versatile multi-tasker to have in your arsenal.

0.2 to 0.4 sec duration


• Hardwearing housing effectively withstands impacts in pressurised environments

• Operating times between 0.2 and 0.4ms for rapid responses

• Wide operating temperature range between -20°C and +80°C for use in harsh conditions

Applications


• Factory automation processes

• Railway applications

• Automotive industry

• Medical and dental equipment

Why are pneumatic timers important?


As they're spark-free, pneumatic timers help regulate your pneumatic system in settings where electrical devices are prohibited, such as the mining, oil and gas industries.

How does a pneumatic timer work?


It uses a piston and control valve to precisely regulate the time it takes for air to exit the system.

Impulse Generator


Fitted between a trip valve and directional control valve when it is necessary to eliminate a trapped or locked pilot signal that would otherwise prevent the control valve from resetting. When an input signal is applied, it generates a short duration output signal, which is then automatically exhausted. A further output signal cannot be generated until the input signal has been removed

Will provide an output signal pressure of 90% of the input pressure. The downstream volume of the tubing and pilot chamber of the control valve should not exceed 0.033 dm3. This volume is equivalent to approximately 6.5 metres of 4mm o/d nylon tube

Impulse duration 0.2 - 0.4s

相關連結

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。