可享批量折扣
小計(1 件)*
TWD9,038.00
(不含稅)
TWD9,489.90
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 加上 83 件從 2025年12月08日 起發貨
- 加上 63 件從 2026年1月27日 起發貨
- 加上 56 件從 2026年2月24日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 - 4 | TWD9,038.00 |
| 5 + | TWD7,440.00 |
* 參考價格
- RS庫存編號:
- 174-9557
- 製造商:
- RS PRO
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | RS PRO | |
| Battery Type | 1.5 V SUM-3 | |
| Power Source | Battery | |
| Weight | 650g | |
| Height | 214mm | |
| Length | 98.7mm | |
| Maximum Operating Temperature | +50°C | |
| Minimum Operating Temperature | 0°C | |
| Model Number p | RS 135 | |
| Width | 56mm | |
| 選取全部 | ||
|---|---|---|
品牌 RS PRO | ||
Battery Type 1.5 V SUM-3 | ||
Power Source Battery | ||
Weight 650g | ||
Height 214mm | ||
Length 98.7mm | ||
Maximum Operating Temperature +50°C | ||
Minimum Operating Temperature 0°C | ||
Model Number p RS 135 | ||
Width 56mm | ||
- COO (Country of Origin):
- TW
RS PRO Current Loop Calibrator and Thermometer
For all current loop repair, calibration and maintenance needs RS PRO presents an easy to use solution. This loop calibrator offers grade precision for temperature measurement and calibration accuracy with a wide measurement range. Source and measure current loops simultaneously. Featuring a clear and easy to read LCD screen, this product is also user friendly and ergonomic with soft touch buttons, built in stand and easy to use settings.
Applications include calibration of 4∼20 mA panel meters, LED brightness testing and temperature calibration of instruments or panel meters for 11 types of thermocouples.
Applications include calibration of 4∼20 mA panel meters, LED brightness testing and temperature calibration of instruments or panel meters for 11 types of thermocouples.
Features and Benefits:
• Source 4∼20 mA, 0∼24 mA with 1 μA resolution (1 KΩ load, 24 V loop supply), basic accuracy 0.025%
• Source 0∼24.000 V with 1 mV resolution
• Source frequency 1∼20000 Hz square wave with programmable duty cycle (1∼99%)
• Auto step and auto ramp for sourcing mA, V
• Easy fixed 25% up and down, or programmable percentage (1∼99%) increase and decrease (mAV)
• Measure DC mA with loop power (24 V output)
• Measure DC V
• Measure Temperature (°C, °F) of 11 types of thermocouples (K, J, E, T, R, S, N, L, U, B and C)
• Calibrator grade precision temperature measurement with 0.1°C & 0.1°F resolution
• Detection of thermocouples disconnection
• Warning for overload, output open (mA) or short (V)
• Short circuit protection for output
• Battery power indication (%) when turn on the calibrator
• Battery supply
• Source 0∼24.000 V with 1 mV resolution
• Source frequency 1∼20000 Hz square wave with programmable duty cycle (1∼99%)
• Auto step and auto ramp for sourcing mA, V
• Easy fixed 25% up and down, or programmable percentage (1∼99%) increase and decrease (mAV)
• Measure DC mA with loop power (24 V output)
• Measure DC V
• Measure Temperature (°C, °F) of 11 types of thermocouples (K, J, E, T, R, S, N, L, U, B and C)
• Calibrator grade precision temperature measurement with 0.1°C & 0.1°F resolution
• Detection of thermocouples disconnection
• Warning for overload, output open (mA) or short (V)
• Short circuit protection for output
• Battery power indication (%) when turn on the calibrator
• Battery supply
Application:
Current loop calibrators are versatile devices used to simulate the operation of loop powered transmitters, source current to unpowered devices in a loop and measure current. With features such as microprocessor based electronics and digital interfaces, they make excellent troubleshooting tools for circuits. Current loop calibrators are commonly used in areas such as:
• Research and development
• Servicing
• Process control engineering
• Calibration technician
• Research and development
• Servicing
• Process control engineering
• Calibration technician
FAQs
What thermocouple types can this work with?
This current loop calibrator with temperature measurement can work with 11 types of thermocouples including K, J, E, T, R, S, N, L, U, B and C.
How much current flows in each loop of a parallel circuit?
Determined by Ohm's law, which states that the current between 2 points through a conductor is directly proportionate to the voltage across those 2 points, divided by the resistance of the conductor. I = V/R. This is also the case for series and parallel circuits, however in parallel circuits the total current can be affected by the way the resistors have been connected, as well as their ohmic value. Current does divide up and there can be more current in one area over another nonetheless when all areas are added up the total amount is the same.
What is included?
• User manual
• Carrying case
• 5 x 1.5 V SUM-3 battery
• K-type thermocouples (1m, single plug)
• 2 x Aligator clips (black and red)
• 2 x test leads (black and red)
• Carrying case
• 5 x 1.5 V SUM-3 battery
• K-type thermocouples (1m, single plug)
• 2 x Aligator clips (black and red)
• 2 x test leads (black and red)
相關連結
- Fluke 789 Multi Function Calibrator
- Fluke 789FC Multi Function Calibrator
- Keysight Technologies N9311X Multi Function Calibrator
- Time Electronics 1006 Multi Function Calibrator
- Time Electronics 1021 Multi Function Calibrator
- Time Electronics 1017 Multi Function Calibrator 100V
- Druck DPI 880 Multi Function Calibrator 30V
- Aoip Instrumentation CALYS 75 Multi Function Calibrator 50V
