ABB, Tmax XT, 1SDA06 Molded Case Circuit Breaker 3-Pole 40A, Breaking Capacity 4 kA, Fixed

小計(1 件)*

TWD10,544.00

(不含稅)

TWD11,071.20

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 2 件準備從其他地點送貨
  • 加上 3 件從 2026年8月21日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD10,544.00

* 參考價格

RS庫存編號:
236-7281
製造零件編號:
1SDA067412R1 XT1N 160 TMD 40A FF
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Product Type

Molded Case Circuit Breaker

Range

Tmax XT

Series

1SDA06

Number of Poles

3

Current Rating

40A

Breaking Capacity

4kA

Mount Type

Fixed

Rated AC Voltage

690V ac

Rated DC Voltage

500V dc

Terminal Type

Screw

Standards/Approvals

IEC

Width

76.2mm

Depth

70mm

Height

130mm

Break Time

Instantaneous

Tripping Mechanism

Thermomagnetic

COO (Country of Origin):
IT

ABB 1SDA06 Series Molded Case Circuit Breaker, 40A Current Rating, 690V AC Rated AC Voltage - 1SDA067412R1 XT1N 160 TMD 40A FF


This moulded-case circuit breaker provides overcurrent protection and isolation for three-phase installations in industrial and commercial electrical systems. It is designed for fixed-panel mounting and offers thermomagnetic tripping for combined thermal overload and magnetic short-circuit response, suiting automation, electrical and mechanical equipment protection requirements.

Features and Benefits:


• 40 A current rating for steady-load protection • 4 kA breaking capacity reduces fault-arc consequences • Instantaneous magnetic trip for Rapid fault interruption • 690V AC and 500V DC ratings for versatile supply types • Screw terminals ensure secure conductor connections • 3‑pole configuration protects three-phase circuits

Applications


• Suitable for motor control panels requiring short-circuit protection • Ideal for switchgear in factory automation systems • Used with DC supply circuits in industrial drives • Can be used for distribution boards in manufacturing plants

What mounting arrangement is required for installation?


It must be mounted in a fixed position within a panel or enclosure designed to accept fixed-mount MCCBs and provide adequate clearance for wiring and ventilation.

How does the tripping mechanism respond to overloads and faults?


A thermomagnetic mechanism combines a thermal element for prolonged overloads and a magnetic element for Rapid instantaneous interruption of high-current faults.

Which standard governs its Basic design characteristics?


The device conforms to IEC performance and testing provisions applicable to low-voltage protective devices.

What connector type is provided for incoming and outgoing conductors?


The unit uses screw-type terminals sized to accept cables appropriate for a 40 A rated breaker.

What panel space and access considerations apply during installation?


Allow for a width of 76.2mm and height of 130mm in the panel layout and ensure 70mm depth clearance behind the mounting plane for proper accommodation.