ABB, Tmax XT, 1SDA06 Molded Case Circuit Breaker 4-Pole 125A, Breaking Capacity 4 kA, Fixed
- RS庫存編號:
- 236-7280
- 製造零件編號:
- 1SDA067409R1 XT1C 160 TMD 125A FF
- 製造商:
- ABB
小計(1 件)*
TWD19,260.00
(不含稅)
TWD20,223.00
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 加上 5 件從 2026年7月27日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD19,260.00 |
* 參考價格
- RS庫存編號:
- 236-7280
- 製造零件編號:
- 1SDA067409R1 XT1C 160 TMD 125A FF
- 製造商:
- ABB
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | ABB | |
| Range | Tmax XT | |
| Product Type | Molded Case Circuit Breaker | |
| Series | 1SDA06 | |
| Number of Poles | 4 | |
| Current Rating | 125A | |
| Breaking Capacity | 4kA | |
| Mount Type | Fixed | |
| Rated AC Voltage | 690V ac | |
| Rated DC Voltage | 500V dc | |
| Terminal Type | Screw | |
| Width | 101.6mm | |
| Height | 130mm | |
| Depth | 70mm | |
| Standards/Approvals | IEC | |
| Break Time | Instantaneous | |
| Tripping Mechanism | Thermomagnetic | |
| 選取全部 | ||
|---|---|---|
品牌 ABB | ||
Range Tmax XT | ||
Product Type Molded Case Circuit Breaker | ||
Series 1SDA06 | ||
Number of Poles 4 | ||
Current Rating 125A | ||
Breaking Capacity 4kA | ||
Mount Type Fixed | ||
Rated AC Voltage 690V ac | ||
Rated DC Voltage 500V dc | ||
Terminal Type Screw | ||
Width 101.6mm | ||
Height 130mm | ||
Depth 70mm | ||
Standards/Approvals IEC | ||
Break Time Instantaneous | ||
Tripping Mechanism Thermomagnetic | ||
- COO (Country of Origin):
- IT
ABB 1SDA06 Series Molded Case Circuit Breaker, 125A Current Rating, 690V AC Rated AC Voltage - 1SDA067409R1 XT1C 160 TMD 125A FF
This moulded case circuit breaker provides overload and short-circuit protection for industrial electrical systems. Designed for fixed installation, it offers four-pole protection and operates with a thermomagnetic trip mechanism suited to mixed fault profiles. It is suitable for use in three-phase and DC distribution arrangements where compact, panel-mounted protection is required.
Features and Benefits:
• 125A rating delivers steady continuous current handling • Thermomagnetic tripping offers combined thermal and magnetic protection • 4kA breaking capacity limits fault energy during short circuits • Rated to 690V AC and 500V DC supports AC and DC networks • Screw terminals ensure secure conductor connections
Applications
• Suitable for motor control panels requiring overcurrent protection • Ideal for distribution boards in industrial automation systems • Used for protection of DC-powered control circuits and battery systems • Can be used in electrical switchgear for manufacturing plants
How is it mounted within an electrical enclosure?
It installs as a fixed-mount device designed for secure panel attachment and stable connection in Compact enclosures.
What Terminal connection method does it use for conductors?
It employs screw-type terminals that provide mechanical retention and electrical contact for a range of cable sizes.
Which standards govern its Basic performance?
It complies with IEC specifications for circuit-breaking performance and safety characteristics.
How does the trip mechanism respond to different fault types?
The thermomagnetic arrangement provides time-delayed response to overloads via the thermal element and instantaneous interruption of high-magnitude faults via the magnetic element.
相關連結
- ABB XT1C Molded Case Circuit Breaker 3-Pole 125A Fixed
- ABB 1SDA06 Molded Case Circuit Breaker 4-Pole 125A Fixed
- ABB 1SDA06 Molded Case Circuit Breaker 4-Pole 80A Fixed
- ABB XT1C Molded Case Circuit Breaker 4-Pole 160A Fixed
- ABB Tmax XT Molded Case Circuit Breaker 3-Pole 20A Fixed
- ABB XT1C Molded Case Circuit Breaker 3-Pole 100A Fixed
- ABB XT1C Molded Case Circuit Breaker 3-Pole 160A Fixed
- ABB XT1C Molded Case Circuit Breaker 3-Pole 40A Fixed