ABB System Pro M Compact S200 Miniature Circuit Breaker, 2-Pole, 16 A, Type D, 400 V ac AC, 125 V DC, 6 kA Breaking

小計(1 件)*

TWD1,933.00

(不含稅)

TWD2,029.65

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 28 件準備從其他地點送貨
  • 加上 21 件從 2026年2月27日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD1,933.00

* 參考價格

RS庫存編號:
746-7863
製造零件編號:
2CDS252001R0161 S202-D16
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Number of Poles

2

Product Type

Miniature Circuit Breaker

Current Rating

16 A

Tripping Characteristics

Type D

Rated AC Voltage

400 V ac

Rated DC Voltage

125 V

Mount Type

DIN Rail

Breaking Capacity

6kA

Range

System Pro M Compact

Series

S200

Terminal Type

Cage Terminal

IP Rating

IP40, IP20

Standards/Approvals

IEC/EN 60898-1, IEC/EN 60947-2

Height

69mm

Depth

69mm

Width

35 mm

Reset Actuator Type

Lever

Tripping Mechanism

Electromagnetic, Thermomagnetic

豁免

COO (Country of Origin):
DE

ABB S200 Series MCB, 16A Current Rating, 10kA Breaking Capacity (at Maximum Voltage Rating) - 2CDS252001R0161 S202-D16


This MCB provides circuit protection for commercial and industrial applications. Its robust construction, along with a thermal electromechanical tripping mechanism, helps ensure safety against overloads and short circuits. The design facilitates easy integration into existing systems while offering high breaking capacity, making it suitable for professionals in electrical and mechanical sectors.

Features & Benefits


• 10kA breaking capacity for effective circuit protection

• Type D circuit breaker tailored for industrial environments

• Thermal electromechanical mechanism ensures precise trip timings

• Short circuit protection enhances safety

• Lever reset actuator simplifies operation

• DIN rail mounted for straightforward installation and maintenance

Applications


• Circuit protection in commercial facilities

• Installation in industrial machinery

• Automation systems within electrical panels

• Residential electrical installations for safety

Can it be installed in older electrical systems?


Yes, the design is compatible with standard fittings, allowing for easy integration.

What is the significance of the tripping characteristic for this device?


The Type D characteristic is sensitive to high inrush currents, making it suitable for inductive loads.

How frequently should it be tested for functionality?


Regular testing is advisable every six months to ensure operational efficiency.

Is there a specific installation procedure to follow?


Adhere to standard DIN rail mounting practices for optimal setup and performance.

What maintenance is required for long-term use?


Periodic inspections for wear and the condition of electrical connections are important to maintain functionality.