Better World
ABB System Pro M Compact S200 MCB, 2P, 8A Curve C, 400V AC, 125V DC, 10 kA Breaking Capacity
- RS庫存編號:
- 746-7700
- 製造零件編號:
- 2CDS252001R0084 S202-C8
- 製造商:
- ABB
小計(1 件)*
TWD1,609.00
(不含稅)
TWD1,689.45
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 15 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD1,609.00 |
* 參考價格
Better World
我們的 Better World 產品系列可讓您輕鬆選擇值得信賴的環保產品。 點擊此處了解更多。
- RS庫存編號:
- 746-7700
- 製造零件編號:
- 2CDS252001R0084 S202-C8
- 製造商:
- ABB
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | ABB | |
| Number of Poles | 2 | |
| Current Rating | 8A | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 400V | |
| Rated DC Voltage | 125V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | System Pro M Compact | |
| Series | S200 | |
| Circuit Breaker Type | MCB | |
| Length | 88mm | |
| Width | 35mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 69mm | |
| Model Number | S202-C8 | |
| Better World Claim | Designed for disassembly | |
| Better World Product | Yes | |
| Reset Actuator Type | Lever | |
| Application | Commercial, Industrial | |
| Special Features | Short Circuit Protection | |
| Terminal Contact Type | Screw | |
| 選取全部 | ||
|---|---|---|
品牌 ABB | ||
Number of Poles 2 | ||
Current Rating 8A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 400V | ||
Rated DC Voltage 125V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range System Pro M Compact | ||
Series S200 | ||
Circuit Breaker Type MCB | ||
Length 88mm | ||
Width 35mm | ||
Mounting Style DIN Rail Mount | ||
Depth 69mm | ||
Model Number S202-C8 | ||
Better World Claim Designed for disassembly | ||
Better World Product Yes | ||
Reset Actuator Type Lever | ||
Application Commercial, Industrial | ||
Special Features Short Circuit Protection | ||
Terminal Contact Type Screw | ||
- COO (Country of Origin):
- DE
ABB S200 Series MCB, 8A Current Rating, 10kA Breaking Capacity (at Maximum Voltage Rating) - 2CDS252001R0084 S202-C8
This MCB is engineered to provide effective protection for electrical circuits in commercial and industrial environments. It safeguards against overloads and short circuits, ensuring safety and dependability in electrical installations. With its advanced thermal and electromechanical tripping mechanism, this circuit breaker caters to the requirements of professionals in the automation and electrical industries, making it a preferred option for numerous applications.
Features & Benefits
• 10kA breaking capacity enhances circuit protection
• Type C MCB suitable for inductive loads
• Versatile design accommodates various industrial MCB solutions
• Lever reset actuator for simple operation
• Sturdy screw terminal contact type for effortless installation
• Environmentally conscious design intended for disassembly
• Type C MCB suitable for inductive loads
• Versatile design accommodates various industrial MCB solutions
• Lever reset actuator for simple operation
• Sturdy screw terminal contact type for effortless installation
• Environmentally conscious design intended for disassembly
Applications
• Protects commercial electrical installations
• Suitable for industrial machinery and automation systems
• Ideal for circuit protection in electrical distribution boards
• Used in requiring robust short circuit protection
• Suitable for industrial machinery and automation systems
• Ideal for circuit protection in electrical distribution boards
• Used in requiring robust short circuit protection
How does the thermal and electromechanical tripping mechanism function?
It provides dual protection using heat-sensitive components and a mechanical system to trip the breaker during overload or short circuit situations.
Is it compatible with existing DIN rail mounting systems?
Yes, it is specifically designed for seamless integration with standard DIN rail mounting setups.
What types of circuits can this be applied to?
It is suitable for circuits that operate inductively, making it appropriate for machinery and various electrical applications.
How often should it be tested for functionality?
Regular testing every six months is advisable to ensure optimal performance and safety.
Can it be reset manually after tripping?
Yes, it features a lever reset actuator that allows for manual resetting following an overload condition.
ABB System Pro M Single & Double Pole MCB's
Note
The Classic & System pro M product cannot be intermixed and do not share common accessories. System pro M products can only be fitted to new style Protecta distribution boards,see typically stock no. 539-1553.
相關連結
- ABB System Pro M Compact S200 MCB 8A Curve D 125V DC, 10 kA Breaking Capacity
- ABB System Pro M Compact S200 MCB 8A Curve K 110V DC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 MCB 40A Curve K 125V DC, 10 kA Breaking Capacity
- ABB System Pro M Compact S200 MCB 32A Curve B 125V DC, 10 kA Breaking Capacity
- ABB System Pro M Compact S200 MCB 50A Curve K 125V DC, 10 kA Breaking Capacity
- ABB System Pro M Compact S200 MCB 25A Curve C 125V DC, 10 kA Breaking Capacity
- ABB System Pro M Compact S200 MCB 32A Curve C 125V DC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 MCB 20A Curve C 125V DC, 6 kA Breaking Capacity