ABB System Pro M Compact S200 Miniature Circuit Breaker, 3-Pole, 1.6 A, Type Z, 400 V ac AC, 6 kA Breaking Capacity

小計(1 件)*

TWD5,691.00

(不含稅)

TWD5,975.55

(含稅)

Add to Basket
選擇或輸入數量
庫存資訊目前無法存取 - 請稍後再回來查看
單位
每單位
1 +TWD5,691.00

* 參考價格

RS庫存編號:
237-3239
製造零件編號:
2CDS253001R0258 S203 Z 1.6A - 10 KA
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Number of Poles

3

Product Type

Miniature Circuit Breaker

Tripping Characteristics

Type Z

Mount Type

DIN Rail

Breaking Capacity

6kA

Range

System Pro M Compact

Series

S200

Terminal Type

Cage Terminal

IP Rating

IP20, IP40

Height

88mm

Standards/Approvals

IEC/EN 60898-1, IEC/EN 60947-2

Depth

69mm

Tripping Mechanism

Electromagnetic, Thermomagnetic

COO (Country of Origin):
DE

ABB S200 Series Miniature Circuit Breaker, 1.6A Current, 6 kA Breaking Capacity - 2CDS253001R0258 S203 Z 1.6A - 10 KA


This miniature circuit breaker provides three-pole overcurrent protection for low-voltage distribution systems and panel assemblies. Designed for DIN-rail mounting within industrial and commercial switchgear, it offers electrical interruption and overload/short-circuit protection using combined thermal and electromagnetic tripping. The device is intended for use where compact, standardised protection is required in automation, electrical and mechanical installations.

Features & Benefits


• 6 kA breaking capacity for effective fault-current interruption
• 1.6A nominal current for low-current circuit protection
• Type Z tripping characteristic for high inrush sensitivity
• Toggle reset actuator for clear manual operation
• Screw terminals to ensure secure conductor connections
• Thermomagnetic trip mechanism for combined overload and short-circuit response

Applications


• Suitable for protecting control circuits in automation cabinets
• Ideal for motor control and distribution feeders with inrush currents
• Used for safeguarding auxiliary circuits in electrical panels
• Can be used for protection in building services and distribution boards

What voltage levels can it be applied to in AC systems?


It is rated for operation on 400V AC systems, suitable for three-phase low-voltage installations.

How is the device mounted within an enclosure?


It is designed to clip onto a standard DIN rail for straightforward panel installation.

What physical form factor affects panel layout?


The device occupies a width of 52.5mm which determines spacing and busbar alignment.

Which ingress protections are specified for its environment?


The enclosure conforms to IP20 and IP40 ratings, indicating protection against finger contact and limited dust ingress depending on mounting configuration.

What tripping technologies are incorporated for fault detection?


The breaker employs both thermal elements for overloads and an electromagnetic element for Rapid short-circuit tripping.

相關連結