ABB System Pro M Compact S200 Miniature Circuit Breaker, 3-Pole, 1 A, Type D, 440 V ac AC, 12 V dc DC, 10 kA Breaking

小計(1 件)*

TWD2,947.00

(不含稅)

TWD3,094.35

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 2 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD2,947.00

* 參考價格

RS庫存編號:
237-3235
製造零件編號:
2CDS253001R0011 S203 D 1A - 10 KA
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Product Type

Miniature Circuit Breaker

Number of Poles

3

Tripping Characteristics

Type D

Breaking Capacity

10kA

Mount Type

DIN Rail

Range

System Pro M Compact

Series

S200

Terminal Type

Cage Terminal

IP Rating

IP20, IP40

Standards/Approvals

IEC/EN 60898-1, IEC/EN 60947-2

Depth

69mm

Height

88mm

Tripping Mechanism

Electromagnetic, Thermomagnetic

Reset Actuator Type

Toggle

COO (Country of Origin):
DE

ABB S200 Series Miniature Circuit Breaker, 1A Current, 400V Rated AC Voltage - 2CDS253001R0011 S203 D 1A - 10 KA


This miniature circuit breaker provides overcurrent protection for three-phase installations in industrial and automation environments. Designed for DIN-rail mounting, it combines thermal and magnetic tripping to respond to both prolonged overloads and short-circuit events while operating within AC and DC systems.

Features & Benefits


• 6kA breaking capacity for secure fault interruption
• Type D tripping to manage high inrush currents
• Thermomagnetic and electromagnetic tripping for dual protection
• Rated for 400V AC and 12V DC operation for versatility
• Screw terminals for robust conductor connections
• 3-pole configuration for three-phase circuit protection

Applications


• Suitable for motor control circuits with high inrush currents
• Used for industrial distribution boards on DIN-rail systems
• Ideal for protection of automation control panels
• can be used in electrical installations requiring Compact breakers
• Suitable for retrofitting into equipment with limited panel space

What mounting method is required for installation?


It mounts on a standard DIN rail, allowing quick installation and alignment with other modular devices.

How does the tripping behaviour handle motor startup?


The Type D characteristic tolerates higher transient currents, so it resists nuisance trips during motor or transformer energisation.

Which connection style is used for conductors?


Screw-type terminals provide a secure mechanical and electrical connection suitable for industrial wiring.

What environmental protection does it provide?


The device has IP20 and IP40 ratings for Basic protection against contact and ingress when mounted in compliant enclosures.

What footprint should be considered for panel layout?


The breaker offers a Compact width of 52.5mm, aiding dense configuration on distribution rails.

相關連結