Eaton xPole PXL, S200 MCB, 1P, 16A Curve B, 400V AC, 48V DC, 10 kA Breaking Capacity
- RS庫存編號:
- 486-883
- 製造零件編號:
- 236033 PXL-B16/1
- 製造商:
- Eaton
可享批量折扣
單價 個**
TWD126.00
(不含稅)
TWD132.30
(含稅)
120 現貨庫存,可於6工作日發貨。*
* 交貨日期可能會根據您選擇的數量和交貨地址而變更。
訂單金額滿 TWD2,857.00 (未稅) 即可享受 免費 送貨服務
單位 | 每單位 |
---|---|
1 - 9 | TWD126.00 |
10 - 24 | TWD122.00 |
25 + | TWD121.00 |
** 參考價格
- RS庫存編號:
- 486-883
- 製造零件編號:
- 236033 PXL-B16/1
- 製造商:
- Eaton
不適用
- COO (Country of Origin):
- AT
PXL series, B characteristic, 1-pole
The PXL series of type B miniature circuit breakers (MCBs) from Eaton's xPole range of MCBs features high quality overcurrent protection that is independent of the mains voltage. These single pole MCBs provide short-circuit interruption that reduces the let-through electrical energy and overload currents that can damage the circuit. The MCB has high selectivity as a pre-fuse with low passband energy. The modular design makes for simple installation of these MCBs into distribution boards and switch circuits whilst additional modules can also be added.
Features and Benefits
Circuit breaker with high selectivity as a pre-fuse with low passband energy
Bus bar compatible
With double terminal, lift / jaw top and bottom
Free selection of rail arrangement top and bottom
Finger-proof / back-of-hand-proof
Quick-fit action with 3 locking positions for top-hat rail IEC / EN 60715
Bus bar compatible
With double terminal, lift / jaw top and bottom
Free selection of rail arrangement top and bottom
Finger-proof / back-of-hand-proof
Quick-fit action with 3 locking positions for top-hat rail IEC / EN 60715
Uses and Applications
The Eaton Miniature circuit breakers (or MCBs) are switchgear for use in industrial, advanced commercial and residential applications.
What are the differences between the Tripping Curves?
Type B: Instantaneous trip when the electrical current through the device is 3 to 5 times the rated current. The type B trip curve MCBs are designed for standard circuit protection, typically protection of generators, persons and very long cables
Type C: Instantaneous trip when the flow-through current is 5 to 10 times the rated current.
Type C trip curve residential and domestic MCBs are used for higher inrush currents such as in machines and lighting, providing overload protection of circuits and other consumer units.
Type D: Instantaneous trip when the flow-through current is 10 to 14 times the rated current.
D curve MCBs are suitable for inductive and capacitive loads like transformers condensers. and electric motors.
Type K: Instantaneous trip when the flow-through current is 10 to 14 times the rated current.
Type K curve MCBs are suitable for inductive loads like transformers, condensers. and electric motors.
Type S: Instantaneous trip when the flow-through current is 13 to 17 times the rated current.
Suitable for applications where high levels of inrush current are expected. The high magnetic trip point of type S curve MCBs prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies.
Type Z: Instantaneous trip when the flow-through current is 2 to 3 times the rated current.
Z curve MCBs are intended for use in electrical circuits that require a very low short circuit trip setting, for example, semiconductors.
Type C: Instantaneous trip when the flow-through current is 5 to 10 times the rated current.
Type C trip curve residential and domestic MCBs are used for higher inrush currents such as in machines and lighting, providing overload protection of circuits and other consumer units.
Type D: Instantaneous trip when the flow-through current is 10 to 14 times the rated current.
D curve MCBs are suitable for inductive and capacitive loads like transformers condensers. and electric motors.
Type K: Instantaneous trip when the flow-through current is 10 to 14 times the rated current.
Type K curve MCBs are suitable for inductive loads like transformers, condensers. and electric motors.
Type S: Instantaneous trip when the flow-through current is 13 to 17 times the rated current.
Suitable for applications where high levels of inrush current are expected. The high magnetic trip point of type S curve MCBs prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies.
Type Z: Instantaneous trip when the flow-through current is 2 to 3 times the rated current.
Z curve MCBs are intended for use in electrical circuits that require a very low short circuit trip setting, for example, semiconductors.
Standards
IEC / EN 60898
Eaton Miniature Circuit Breaker, 1 Pole, Type B - PXL Series - PXL-B16/1
Looking for reliable overcurrent protection that's independent of the mains voltage? This Eaton single-pole MCB (miniature circuit breaker) interrupts short circuits and reduces damaging overload current. You can easily install it in distribution boards and switch circuits thanks to its quick-fit action with three locking positions for top-hat rail IEC and EN 6071. It also features dual terminals, which are compatible with both busbars and cables. A red-green indicator makes it easy to identify the contact position, which increases safety and protects the operator.
• Rated to 400V and 48V DC at 16A for versatility
• Type B tripping characteristic gives instantaneous trip when the current through the device is 3 to 5 times the rated current
• Compact size of 60 (W) x 17.5 (L) x 80mm (D) for easy handling
• Toggle is finger-proof and back-of-hand-proof to avoid accidental tripping
• Type B tripping characteristic gives instantaneous trip when the current through the device is 3 to 5 times the rated current
• Compact size of 60 (W) x 17.5 (L) x 80mm (D) for easy handling
• Toggle is finger-proof and back-of-hand-proof to avoid accidental tripping
Where can I use this MCB?
Type B trip curve MCBs are designed to protect circuits with equipment that doesn't cause surge current, like lighting and distribution circuits. They are widely used for residential applications and domestic appliances.
Standards
IEC / EN 60898
屬性 | 值 |
---|---|
Number of Poles | 1P |
Current Rating | 16A |
Tripping Characteristics | Type B |
Rated AC Voltage | 400V |
Rated DC Voltage | 48V |
Breaking Capacity at Maximum Voltage Rating | 10 kA |
Range | xPole |
Series | PXL, S200 |
Circuit Breaker Type | MCB |
Width | 80mm |
Length | 17.5mm |
Mounting Style | DIN Rail Mount |
Depth | 60mm |
Model Number | PXL-B16/1 |
Application | Commercial, Residential |
Break Time | Instantaneous |