Eaton xPole PXL, S200 MCB, 2P, 16A Curve C, 400V AC, 48V DC, 10 kA Breaking Capacity

可享批量折扣

小計(1 件)*

TWD1,981.00

(不含稅)

TWD2,080.05

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 加上 7 件從 2026年1月05日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 - 4TWD1,981.00
5 - 9TWD1,896.00
10 +TWD1,866.00

* 參考價格

RS庫存編號:
490-179
製造零件編號:
236289 PXL-C16/2
製造商:
Eaton
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Eaton

Number of Poles

2

Current Rating

16A

Tripping Characteristics

Type C

Rated AC Voltage

400V

Rated DC Voltage

48V

Breaking Capacity at Maximum Voltage Rating

10 kA

Range

xPole

Series

PXL, S200

Circuit Breaker Type

MCB

Length

35mm

Width

80mm

Mounting Style

DIN Rail Mount

Depth

60mm

豁免

COO (Country of Origin):
AT

Eaton MCB, 16A Current Rating, Type C Tripping Characteristics - 236289 PXL-C16/2


This Eaton MCB is a high-performance 2-pole circuit breaker designed for efficient electrical protection in residential and commercial applications. Measuring 80mm in length and 35mm in width, it has a rated current of 16A and accommodates up to 400V AC. This device is an integral part of the xPole range, providing reliable circuit protection with its robust breaking capacity.

Features & Benefits


• Complies with IEC/EN 60898-1 for reliable performance
• Ensures high breaking capacity of 10 kA for robust protection
• Type C tripping characteristic for motor protection
• Compatible with standard DIN rail for seamless installation
• Toggle switch for straightforward manual reset and operation
• Effective across a wide temperature range, -25°C to 55°C

Applications


• Used with electrical systems in residential installations
• Applicable for commercial electrical distribution panels
• Ideal for automation and control systems integration
• Suitable for protecting electrical circuits against overloads
• Designed for use in environments requiring compact circuit protection

What is the importance of the Type C tripping characteristic?


Type C tripping characteristics are essential for circuits with moderate overloads, especially in industrial applications where inductive loads are common, preventing nuisance tripping.

How does temperature affect the performance of this circuit breaker?


With an operational temperature range of -25°C to 55°C, significant temperature increases can reduce its current-carrying capacity, an aspect crucial for ensuring consistent performance in warmer environments.

What is the significance of the 10 kA breaking capacity?


A breaking capacity of 10 kA indicates the maximum fault current the device can interrupt without failure, ensuring safety in more demanding electrical installations.

Note

Eaton formerly known as Moeller

Standards

IEC / EN 60898

相關連結