Eaton xPole PXL, S200 MCB, 1P, 16A Curve C, 400V AC, 48V DC, 10 kA Breaking Capacity
- RS庫存編號:
- 486-805
- 製造零件編號:
- 236059 PXL-C16/1
- 製造商:
- Eaton
可享批量折扣
小計(1 件)*
TWD277.00
(不含稅)
TWD290.85
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 12 件準備從其他地點送貨
- 加上 24 件從 2026年1月07日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 - 9 | TWD277.00 |
| 10 - 24 | TWD266.00 |
| 25 + | TWD256.00 |
* 參考價格
- RS庫存編號:
- 486-805
- 製造零件編號:
- 236059 PXL-C16/1
- 製造商:
- Eaton
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Eaton | |
| Number of Poles | 1 | |
| Current Rating | 16A | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 400V | |
| Rated DC Voltage | 48V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | xPole | |
| Series | PXL, S200 | |
| Circuit Breaker Type | MCB | |
| Width | 80mm | |
| Length | 17.5mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 60mm | |
| 選取全部 | ||
|---|---|---|
品牌 Eaton | ||
Number of Poles 1 | ||
Current Rating 16A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 400V | ||
Rated DC Voltage 48V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range xPole | ||
Series PXL, S200 | ||
Circuit Breaker Type MCB | ||
Width 80mm | ||
Length 17.5mm | ||
Mounting Style DIN Rail Mount | ||
Depth 60mm | ||
豁免
- COO (Country of Origin):
- AT
Eaton MCB, 16A Current Rating, Type C Tripping Characteristics - 236059 PXL-C16/1
This miniature circuit breaker (MCB) is designed for effective electrical circuit protection, offering robust performance in residential and commercial applications. With a width of 17.5mm and a length of 80mm, it is expertly configured for DIN rail mounting, ensuring ease of installation. The Eaton xPole MCB features a Type C tripping characteristic, making it an efficient choice for safeguarding electrical circuits from overcurrents and short circuits.
Features & Benefits
• 16A current rating ensures adequate protection for circuits
• Type C MCB provides efficient response to overloads
• 10 kA breaking capacity accommodates high fault current scenarios
• Designed for easy DIN rail mounting for quick setup
• Toggle switch actuator simplifies operation and resetting
• Compatible with multi-wired and solid-core conductors up to 25mm²
• Type C MCB provides efficient response to overloads
• 10 kA breaking capacity accommodates high fault current scenarios
• Designed for easy DIN rail mounting for quick setup
• Toggle switch actuator simplifies operation and resetting
• Compatible with multi-wired and solid-core conductors up to 25mm²
Applications
• Integrated into residential electrical systems
• Utilised in commercial switchgear installations
• Ideal for requiring enhanced electrical safety
• Suitable for environments with varying electrical loads
• Utilised in commercial switchgear installations
• Ideal for requiring enhanced electrical safety
• Suitable for environments with varying electrical loads
What are the operational parameters regarding the ambient temperature?
This device functions effectively within a temperature range of -25 °C to 55 °C, ensuring reliable performance in diverse environments.
How does the breaking capacity influence the product's suitability for use?
With a rated breaking capacity of 10 kA, it effectively manages high current faults, thus minimising damage and improving the lifespan of the connected circuit.
What installation considerations should be taken into account?
Ensure the mounting rail complies with standard specifications for secure installation, and verify conductor cross-sections are within the acceptable range for optimal connectivity.
Standards
IEC / EN 60898
相關連結
- Eaton xPole PXL 2P 400V AC 10 kA Breaking Capacity
- Eaton xPole PXL 3P 400V AC 10 kA Breaking Capacity
- Eaton xPole PXL 1P 400V AC 10 kA Breaking Capacity
- Eaton xPole - PXL PXL MCB 16A Curve C 48V DC
- Eaton xPole PXL 1P 400V AC 10 kA Breaking Capacity
- Eaton xPole PXL 1P 400V AC 10 kA Breaking Capacity
- Eaton xPole PXL 1P 400V AC 10 kA Breaking Capacity
- Eaton xPole PXL 1P 400V AC 10 kA Breaking Capacity