Telemecanique Sensors ZCD Series Roller Lever Limit Switch, 2 NC, IP66, IP67, Zinc Alloy Housing, 240V ac, 1.5A
- RS庫存編號:
- 221-2051
- 製造零件編號:
- ZCD29
- 製造商:
- Telemecanique Sensors
小計(1 件)*
TWD2,106.00
(不含稅)
TWD2,211.30
(含稅)
訂單超過 $1,300.00 免費送貨
暫時缺貨
- 從 2026年12月01日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD2,106.00 |
* 參考價格
- RS庫存編號:
- 221-2051
- 製造零件編號:
- ZCD29
- 製造商:
- Telemecanique Sensors
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Telemecanique Sensors | |
| Product Type | Limit Switch | |
| Actuator Type | Roller Lever | |
| IP Rating | IP66, IP67 | |
| Contact Configuration | 2 NC | |
| Housing Material | Zinc Alloy | |
| Contact Type | Snap Action | |
| Terminal Type | Screw Clamp | |
| Switching Current | 1.5A | |
| Series | ZCD | |
| Minimum Operating Temperature | -25°C | |
| Switching DC Voltage | 250V dc | |
| Switching AC Voltage | 240V ac | |
| Maximum Operating Temperature | 70°C | |
| Standards/Approvals | CSA C22.2 No 14, UL 508, EN/IEC 60947-5-1, IEC 60664, IEC 60947-1 | |
| Width | 31mm | |
| Length | 30mm | |
| Depth | 65mm | |
| Hazardous Area Certification | No | |
| Mounting Orientation | Side | |
| Conduit Entry | 20 mm | |
| Mechanical Life | 5000000Cycles | |
| 選取全部 | ||
|---|---|---|
品牌 Telemecanique Sensors | ||
Product Type Limit Switch | ||
Actuator Type Roller Lever | ||
IP Rating IP66, IP67 | ||
Contact Configuration 2 NC | ||
Housing Material Zinc Alloy | ||
Contact Type Snap Action | ||
Terminal Type Screw Clamp | ||
Switching Current 1.5A | ||
Series ZCD | ||
Minimum Operating Temperature -25°C | ||
Switching DC Voltage 250V dc | ||
Switching AC Voltage 240V ac | ||
Maximum Operating Temperature 70°C | ||
Standards/Approvals CSA C22.2 No 14, UL 508, EN/IEC 60947-5-1, IEC 60664, IEC 60947-1 | ||
Width 31mm | ||
Length 30mm | ||
Depth 65mm | ||
Hazardous Area Certification No | ||
Mounting Orientation Side | ||
Conduit Entry 20 mm | ||
Mechanical Life 5000000Cycles | ||
- COO (Country of Origin):
- ID
Telemecanique Sensors ZCD Series Limit Switch, IP66 and IP67, Zinc Alloy Housing - ZCD29
This limit switch provides position detection and circuit switching for industrial machinery using a roller lever actuator and snap-action contacts. It is intended for side-mounted installation in systems requiring weatherproof operation and Compact switching capability across a broad ambient temperature range.
Features and Benefits:
• IP66/IP67 enclosure for dust-tight and temporary immersion protection
• Zinc alloy housing offering robust mechanical protection
• 2NC contact arrangement for dual normally closed control circuits
• Snap-action contacts delivering swift switching at 1.5A
• 250V dc and 240V ac switching capability for varied power systems
• Screw-clamp terminals enabling secure conductor connections
• Zinc alloy housing offering robust mechanical protection
• 2NC contact arrangement for dual normally closed control circuits
• Snap-action contacts delivering swift switching at 1.5A
• 250V dc and 240V ac switching capability for varied power systems
• Screw-clamp terminals enabling secure conductor connections
Applications
• Suitable for conveyor end-of-travel detection in manufacturing
• Ideal for gate position sensing in outdoor installations
• Used for safety interlocks where side mounting is required
• Can be used for machine stop signalling in automation lines
• Suitable for equipment operating between -25°C and 70°C
• Ideal for gate position sensing in outdoor installations
• Used for safety interlocks where side mounting is required
• Can be used for machine stop signalling in automation lines
• Suitable for equipment operating between -25°C and 70°C
What conduit entry is provided for cable routing?
A 20 mm conduit entry is supplied for conduit or gland attachment.
How long is the expected mechanical service before replacement?
The mechanism is rated for 5,000,000 cycles of mechanical life.
What approvals confirm compatibility with industrial electrical standards?
It meets CSA C22.2 No 14, UL 508, EN/IEC 60947-5-1, IEC 60664 and IEC 60947-1.
Which mounting orientation is recommended for reliable actuation?
The device is designed for side mounting to suit lever actuation geometry.
What Terminal type should installers expect when wiring?
The switch uses screw-clamp terminals for conductor fastening.
相關連結
- Telemecanique Sensors ZCD Series Limit Switch IP66 Zinc Alloy Housing 1.5A
- Telemecanique Sensors ZCD Series Limit Switch Body IP66 Zamak Housing 1.5A
- Telemecanique Sensors ZCD Series Roller Lever Limit Switch IP66 Zinc Alloy Housing, 240V ac
- Telemecanique Sensors XCKJ Series Roller Lever Limit Switch IP66 240V ac, 1.5A
- Telemecanique Sensors ZCD Series Roller Lever Limit Switch IP66 Zinc Alloy Housing 0.75A
- Telemecanique Sensors OsiSense ATEX D Series Roller Lever Limit Switch IP67 240V ac, 1.5A
- Telemecanique Sensors XCSM Series Roller Lever Limit Switch IP68 IP66 1.5A
- Telemecanique Sensors ZCKM Series Roller Lever Limit Switch IP66 240V ac, 1.5A
