規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Endress+Hauser | |
| Product Type | Level Switch | |
| Device Type | Conductive Level Switch | |
| Mount Type | Threaded Mount | |
| Housing Material | Polybutylene Terephthalate Fibre Reinforced | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 100°C | |
| Maximum AC Voltage | 230V ac | |
| Maximum DC Voltage | 55V dc | |
| Maximum Pressure | 10bar | |
| Standards/Approvals | CE mark | |
| Hazardous Area Certification | ATEX | |
| Series | FTW31 | |
| 選取全部 | ||
|---|---|---|
品牌 Endress+Hauser | ||
Product Type Level Switch | ||
Device Type Conductive Level Switch | ||
Mount Type Threaded Mount | ||
Housing Material Polybutylene Terephthalate Fibre Reinforced | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 100°C | ||
Maximum AC Voltage 230V ac | ||
Maximum DC Voltage 55V dc | ||
Maximum Pressure 10bar | ||
Standards/Approvals CE mark | ||
Hazardous Area Certification ATEX | ||
Series FTW31 | ||
- COO (Country of Origin):
- DE
Endress+Hauser FTW31 Series Level Switch, +70°C Maximum Operating Temperature, 10 Bar Maximum Pressure - FTW31-A1A2CA0A
This level switch is a conductive sensor designed to detect liquid presence in industrial settings. It operates across a wide ambient range and is intended for threaded installation where simple, reliable point-level detection is required. The unit is manufactured with a reinforced thermoplastic enclosure and a resilient sealing element to suit process plants that demand compact, electrically simple level control.
Features and Benefits:
• Operates between -40°C and +70°C for wide thermal tolerance
• Withstands process pressures up to 10 bar for pressurised vessels
• Accepts up to 230V AC or 55V DC for versatile electrical supply options
• Switch output limited to 25mA to suit low-current control circuits
• Fibre-reinforced polybutylene terephthalate housing for mechanical resistance
• Ethylene propylene diene monomer gasket for chemical and temperature resilience
• Withstands process pressures up to 10 bar for pressurised vessels
• Accepts up to 230V AC or 55V DC for versatile electrical supply options
• Switch output limited to 25mA to suit low-current control circuits
• Fibre-reinforced polybutylene terephthalate housing for mechanical resistance
• Ethylene propylene diene monomer gasket for chemical and temperature resilience
Applications
• Suitable for point-level detection in storage tanks and sumps
• Ideal for retrofitting into existing threaded ports on process vessels
• Used for overfill protection in non-explosive and hazardous-area zones
• Can be used for pump control where conductive sensing is acceptable
• Used with low-power control systems requiring discrete switching
• Ideal for retrofitting into existing threaded ports on process vessels
• Used for overfill protection in non-explosive and hazardous-area zones
• Can be used for pump control where conductive sensing is acceptable
• Used with low-power control systems requiring discrete switching
What mounting method is required for installation?
It fits a threaded mount arrangement and is intended to be screwed into appropriate process ports or fittings.
How does the device behave electrically when used in control loops?
The sensor offers a low-current switching capability up to 25mA and can be powered from AC mains at 230V or DC supplies up to 55V, enabling direct interface with low-power indicators or control relays.
What materials protect the sensor from process environments?
The enclosure is made from fibre-reinforced polybutylene terephthalate and the seal is an EPDM-type elastomer to provide resistance against mechanical stress and common media.
Is the unit suitable for hazardous-area installations?
It carries ATEX certification indicating it meets required standards for deployment in specified explosive atmospheres.
What certification indicates conformity with regional requirements?
The device bears CE marking to show compliance with applicable European directives.
相關連結
- Endress+Hauser FTW31 Series Conductive Level Switch ATEX-Rated, Housing Polybutylene Terephthalate
- Endress+Hauser Liquipoint T FTW31 Series Conductive Level Sensor ATEX-Rated, Housing Polybutylene
- Endress+Hauser FTW31 Series Conductive Level Switch Level Switch Housing Polypropylene
- Endress+Hauser FTW32 Series Conductive Level Switch ATEX-Rated, Housing Polybutylene Terephthalate
- Endress+Hauser FTW325 Series Conductive Level Switch ATEX-Rated, Housing Polycarbonate
- Endress+Hauser Liquipoint T FTW32 Series Conductive Level Sensor ATEX-Rated, Housing Polybutylene
- Endress+Hauser FTM20 Series Vibration Level Switch Level Switch ATEX Housing Polybutylene
- Endress+Hauser FTM20 Series Vibration Level Switch Level Switch IECEx Housing Polybutylene