Endress+Hauser Nivotester FTW325 Series Capacitance Level Switch, DIN Rail, ATEX-Rated, Housing Polycarbonate

小計(1 件)*

TWD10,948.00

(不含稅)

TWD11,495.40

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 加上 9 件從 2026年8月31日 起發貨
  • 加上 6 件從 2026年9月01日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD10,948.00

* 參考價格

RS庫存編號:
288-6482
Distrelec 貨號:
304-08-405
製造零件編號:
FTW325-C2B1A
製造商:
Endress+Hauser
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Endress+Hauser

Product Type

Level Switch

Device Type

Capacitance

Mount Type

DIN Rail

Housing Material

Polycarbonate

Minimum Operating Temperature

-20°C

Maximum Operating Temperature

60°C

Maximum AC Voltage

30V ac

Standards/Approvals

CE mark

Hazardous Area Certification

ATEX

Series

Nivotester FTW325

COO (Country of Origin):
DE

Endress+Hauser FTW325 Series Level Switch, 60°C Maximum Operating Temperature, Polycarbonate Housing Material - FTW325-C2B1A


This level switch is a capacitance-based detector designed for monitoring material presence in industrial installations. It mounts on a DIN rail and is suited to hazardous-area environments where intrinsic safety and compact installation are required. The unit operates across a typical industrial temperature range and interfaces with low-voltage AC control circuits.

Features and Benefits:


• Polycarbonate housing offers chemical-resistant, lightweight enclosure
• ATEX hazardous-area certification enables use in explosive atmospheres
• Operates reliably between -20°C and 60°C for broad thermal range
• Maximum AC input 30V AC ensures compatibility with low-voltage systems
• Switching current up to 60mA supports direct drive of small control loads

Applications


• Suitable for point-level indication in chemical dosing tanks
• Ideal for integration into control panels on DIN rails
• Used for level detection in solvent-handling processes in hazardous zones
• Can be used for monitoring bulk solids or slurries where capacitance sensing is required

How is the device mounted within control cabinets?


It clips onto standard DIN rail profiles for straightforward panel installation and wiring access.

What material protects the electronics from environmental exposure?


The enclosure is formed from polycarbonate to shield internal components from dust and splash conditions.

What electrical load can the switch directly handle?


The output circuit is rated to carry currents up to 60mA at a maximum of 30V AC for direct interfacing with small relays or indicators.

Is the unit suitable for use in explosive atmospheres?


It holds ATEX certification which permits deployment in zones requiring certified equipment for hazardous environments.