Chauvin Arnoux MX604 Insulation Tester, 50 V Min, 500 V Max, 2000 CAT III
- RS庫存編號:
- 229-8921
- 製造零件編號:
- MX0604
- 製造商:
- Chauvin Arnoux
小計(1 件)*
TWD55,742.00
(不含稅)
TWD58,529.10
(含稅)
訂單超過 $1,300.00 免費送貨
製造商存貨
- 準備從 2026年10月26日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD55,742.00 |
* 參考價格
- RS庫存編號:
- 229-8921
- 製造零件編號:
- MX0604
- 製造商:
- Chauvin Arnoux
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Chauvin Arnoux | |
| Product Type | Insulation Tester | |
| Model Number | MX604 | |
| Tester Type | Insulation Tester | |
| Maximum Test Voltage | 500V | |
| Minimum Test Voltage | 50V | |
| Display Type | Analogue | |
| Test Current | 200mA | |
| Battery Type | LR03 | |
| Power Source | 1.5 V Battery | |
| Minimum Operating Temperature | 0°C | |
| Insulation Testing Resistance | 2000 | |
| Safety Category Level | CAT III | |
| Safety Category Voltage | 300V | |
| Maximum Operating Temperature | 45°C | |
| Height | 155mm | |
| Width | 98mm | |
| Standards/Approvals | IEC 61010 safety standard | |
| 選取全部 | ||
|---|---|---|
品牌 Chauvin Arnoux | ||
Product Type Insulation Tester | ||
Model Number MX604 | ||
Tester Type Insulation Tester | ||
Maximum Test Voltage 500V | ||
Minimum Test Voltage 50V | ||
Display Type Analogue | ||
Test Current 200mA | ||
Battery Type LR03 | ||
Power Source 1.5 V Battery | ||
Minimum Operating Temperature 0°C | ||
Insulation Testing Resistance 2000 | ||
Safety Category Level CAT III | ||
Safety Category Voltage 300V | ||
Maximum Operating Temperature 45°C | ||
Height 155mm | ||
Width 98mm | ||
Standards/Approvals IEC 61010 safety standard | ||
- COO (Country of Origin):
- FR
The Metrix MX604 surge arrester and megohmmeter enables to test easily and quickly without any risk, between 0 and 600 VDC. A support module connects to the instrument and allows the dismantled surge arresters to be inserted for the tests to be carried out. The MX604 enables the insulation resistance of telephone lines, e.g. between the subscriber and the secondary distribution frame, to be measured.
Includes a probe with remote control button for on-site measurements
Measures insulation resistances at 50, 100 and 500 VDC
An indicator light warns of the presence of mains voltage
Enables direct reading of results whatever the function chosen
相關連結
- Chauvin Arnoux Earth Tester CAT III 42V
- Chauvin Arnoux Insulation & Continuity Tester 500 V Max CAT IV
- Chauvin Arnoux Insulation & Continuity Tester 100 V Max CAT IV
- Chauvin Arnoux Insulation & Continuity Tester 100 V Max CAT IV
- Chauvin Arnoux Earth Tester, 99.9 kΩ CAT III 50V
- Chauvin Arnoux Earth Tester Kit, 100 kΩ CAT IV
- Chauvin Arnoux Earth Tester, 400 kΩ CAT III 600V
- Chauvin Arnoux CA 6503 Insulation Tester 1000 V Max CAT II