Chauvin Arnoux MX604 Insulation Tester, 50 V Min, 500 V Max, 2000 CAT III
- RS庫存編號:
- 229-8921
- 製造零件編號:
- MX0604
- 製造商:
- Chauvin Arnoux
小計(1 件)*
TWD55,742.00
(不含稅)
TWD58,529.10
(含稅)
訂單超過 $1,300.00 免費送貨
製造商存貨
- 準備從 2026年11月16日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD55,742.00 |
* 參考價格
- RS庫存編號:
- 229-8921
- 製造零件編號:
- MX0604
- 製造商:
- Chauvin Arnoux
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Chauvin Arnoux | |
| Model Number | MX604 | |
| Product Type | Insulation Tester | |
| Tester Type | Insulation Tester | |
| Minimum Test Voltage | 50V | |
| Maximum Test Voltage | 500V | |
| Display Type | Analogue | |
| Test Current | 200mA | |
| Battery Type | LR03 | |
| Power Source | 1.5 V Battery | |
| Insulation Testing Resistance | 2000 | |
| Minimum Operating Temperature | 0°C | |
| Maximum Operating Temperature | 45°C | |
| Safety Category Level | CAT III | |
| Safety Category Voltage | 300V | |
| Height | 155mm | |
| Standards/Approvals | IEC 61010 safety standard | |
| Width | 98mm | |
| 選取全部 | ||
|---|---|---|
品牌 Chauvin Arnoux | ||
Model Number MX604 | ||
Product Type Insulation Tester | ||
Tester Type Insulation Tester | ||
Minimum Test Voltage 50V | ||
Maximum Test Voltage 500V | ||
Display Type Analogue | ||
Test Current 200mA | ||
Battery Type LR03 | ||
Power Source 1.5 V Battery | ||
Insulation Testing Resistance 2000 | ||
Minimum Operating Temperature 0°C | ||
Maximum Operating Temperature 45°C | ||
Safety Category Level CAT III | ||
Safety Category Voltage 300V | ||
Height 155mm | ||
Standards/Approvals IEC 61010 safety standard | ||
Width 98mm | ||
- COO (Country of Origin):
- FR
The Metrix MX604 surge arrester and megohmmeter enables to test easily and quickly without any risk, between 0 and 600 VDC. A support module connects to the instrument and allows the dismantled surge arresters to be inserted for the tests to be carried out. The MX604 enables the insulation resistance of telephone lines, e.g. between the subscriber and the secondary distribution frame, to be measured.
Includes a probe with remote control button for on-site measurements
Measures insulation resistances at 50, 100 and 500 VDC
An indicator light warns of the presence of mains voltage
Enables direct reading of results whatever the function chosen
相關連結
- Chauvin Arnoux MH401 Insulation Tester 1 kV Max, 2000 mΩ CAT III
- Chauvin Arnoux Insulation Tester 1 kV Max, 4 TΩ CAT III
- Chauvin Arnoux CA 6513 Insulation Tester 1 kV Max CAT III
- Chauvin Arnoux CA 6503 Insulation Tester 1 kV Max CAT II
- Chauvin Arnoux Earth Tester CAT III 42V
- Chauvin Arnoux CA 6505 Insulation Tester 5100 V Max, 10 TΩ CAT III
- Chauvin Arnoux Earth Tester, 400 kΩ CAT III 600V
- Chauvin Arnoux Earth Tester, 99.9 kΩ CAT III 50V