Chauvin Arnoux CA 6550 Insulation Tester, 40 V Min, 10000 V Max CAT IV
- RS庫存編號:
- 237-2905
- 製造零件編號:
- P01139715
- 製造商:
- Chauvin Arnoux
小計(1 件)*
TWD291,438.00
(不含稅)
TWD306,009.90
(含稅)
庫存資訊目前無法存取 - 請稍後再回來查看
單位 | 每單位 |
|---|---|
| 1 + | TWD291,438.00 |
* 參考價格
- RS庫存編號:
- 237-2905
- 製造零件編號:
- P01139715
- 製造商:
- Chauvin Arnoux
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Chauvin Arnoux | |
| Product Type | Insulation Tester | |
| Model Number | CA 6550 | |
| Tester Type | Insulation Tester | |
| Maximum Test Voltage | 10000V | |
| Minimum Test Voltage | 40V | |
| Display Type | LCD | |
| Battery Life | 2h | |
| Power Source | Battery | |
| Safety Category Level | CAT IV | |
| Safety Category Voltage | 1000V | |
| Width | 300mm | |
| Standards/Approvals | CE | |
| Height | 200mm | |
| Length | 340mm | |
| Weight | 6.2kg | |
| 選取全部 | ||
|---|---|---|
品牌 Chauvin Arnoux | ||
Product Type Insulation Tester | ||
Model Number CA 6550 | ||
Tester Type Insulation Tester | ||
Maximum Test Voltage 10000V | ||
Minimum Test Voltage 40V | ||
Display Type LCD | ||
Battery Life 2h | ||
Power Source Battery | ||
Safety Category Level CAT IV | ||
Safety Category Voltage 1000V | ||
Width 300mm | ||
Standards/Approvals CE | ||
Height 200mm | ||
Length 340mm | ||
Weight 6.2kg | ||
- COO (Country of Origin):
- FR
The Chauvin Arnoux CA 6550 and CA 6555 megohmmeter are tools of excellence to perform insulation checks with safety and precision. Their use on equipment and rotating machines, operating at 12 kV and above, complies with recommended practices. The multiple test modes allow both qualitatively qualifying non-control isolations. Also it investigate the problems on samples of insulation aging for the purpose of preventive maintenance.
Measuring range from 10 kΩ to 30 TΩ
Fixed or programmable test voltage from 40 V to 10/15 kV
5 mA load current
Real-time graphic display R (t) + u (t), i (t), i (u)
DAR / PI / DD / ΔR ratios (ppm / V)
Ramp and voltage step modes with burning mode,
"Early break" and "I-limit"
3 filters to optimize measurement stability
Calculation of R at a reference temperature
Memory capacity 80,000 measurements and Real time clock
Report generation via DataView software
相關連結
- Chauvin Arnoux CA 6550 Insulation Tester 10000V Max CAT IV 1000 V
- Chauvin Arnoux CA 6555 Insulation Tester 15000 V Max CAT IV
- Chauvin Arnoux Earth Tester Kit, 100 kΩ CAT IV
- Chauvin Arnoux Insulation & Continuity Tester 100 V Max CAT IV
- Chauvin Arnoux Insulation & Continuity Tester 100 V Max CAT IV
- Chauvin Arnoux Insulation & Continuity Tester 500 V Max CAT IV
- Chauvin Arnoux CA 6536 Insulation Tester 100V Max CAT IV 600 V
- Chauvin Arnoux Earth Tester Kit, 100 kΩ CAT IV 50V