Sensata Cynergy3 SSF67 Series Vertical Stainless Steel Float Switch, Float, 1m Cable, NO/NC, 250V ac Max, 120V dc Max
- RS庫存編號:
- 756-4182
- 製造零件編號:
- SSF67A25B300
- 製造商:
- Sensata / Cynergy3
可享批量折扣
單價 個**
TWD9,997.00
(不含稅)
TWD10,496.85
(含稅)
8 在6 工作日內發貨 (海外庫存)*
5 在6 工作日內發貨 (海外庫存)
* 交貨日期可能會根據您選擇的數量和交貨地址而變更。
訂單金額滿 TWD2,857.00 (未稅) 即可享受 免費 送貨服務
單位 | 每單位 |
---|---|
1 - 5 | TWD9,997.00 |
6 + | TWD9,747.00 |
** 參考價格
- RS庫存編號:
- 756-4182
- 製造零件編號:
- SSF67A25B300
- 製造商:
- Sensata / Cynergy3
- COO (Country of Origin):
- TW
Sensata Cynergy3 Float Switch, Dual Switching Levels, 10 Bar Maximum Pressure - SSF67 Series - SSF67A25B300
If you are looking for a reliable way to control sensitive liquids, then our range of float switches from Cynergy3 is an economical and efficient choice. We offer float switches which are easy to install in tanks and hard to reach places and comes with low maintenance.
• Cable length of 1m for a flexible connection between your control module and the power supply
• Mounts at the top or bottom of the tank for use in setups with no side access
• Compatible with fluids that have a minimum specific gravity of 0.8 for versatility
• ETFE cable sheath withstands high temperatures for safety in harsh environments
• Mounts at the top or bottom of the tank for use in setups with no side access
• Compatible with fluids that have a minimum specific gravity of 0.8 for versatility
• ETFE cable sheath withstands high temperatures for safety in harsh environments
What is a float switch?
A SSF67A25B300 switch is the type of level sensor, a gadget to recognize the level of fluid inside a tank. The switch might be utilized to control a pump, as a pointer, a caution, or to control different gadgets. It consists of reed switch and a pivoted magnet and can be used for normally open (N/O) or normally closed (N/C) operation. The switch action can be reversed rotating the switch through 180°.
Features and Benefits
• Two Independent Switching Points
• Maximum temperature 135 °C
• Minimum Fluid SG(Specific Gravities): 0.80
• Suitable for high and low level alarm and control signal
• Manufactured in Stainless Steel 316L material
• Maximum temperature 135 °C
• Minimum Fluid SG(Specific Gravities): 0.80
• Suitable for high and low level alarm and control signal
• Manufactured in Stainless Steel 316L material
Guide how to choose the correct float switch
One of the most reliable, well-demonstrated technologies for fluid level detecting is float switch. This sort of switch involves a magnet contained inside a float, and also an attractive reed switch contained inside a settled housing. The movement of float, due to changing fluid level, will cause the reed change to work (for instance close or open) at specific level. This trusted and tried technology depends on a generally straightforward plan that offers long haul quality without the requirement for the client to calibrate a switch.
There are different methods available how to choose a float switch for particular application, here are the main factors to consider:
There are different methods available how to choose a float switch for particular application, here are the main factors to consider:
Physical arrangement and style
The choice of styles depends on the physical arrangement of the tank, availability of mounting positions and whether there is an access inside of the tank.
Fundamental styles are horizontal / side mounting and vertical mounting. Horizontal / side mounting has a fixed housing, which you can find on the wall of a tank and it has got a hinged float attached to the fixed housing. Vertical usually have a fixed vertical stem and that is installed at the top or bottom of the tank.
Fundamental styles are horizontal / side mounting and vertical mounting. Horizontal / side mounting has a fixed housing, which you can find on the wall of a tank and it has got a hinged float attached to the fixed housing. Vertical usually have a fixed vertical stem and that is installed at the top or bottom of the tank.
Material selection
It is very important to choose a float switch that is made from right materials, which are compatible with the liquids and temperatures of the chosen application. While using incorrect material it can resolve in damaging of the component as well as failure of a float switch.
Material types:
• Nylon – used for oils, diesel, organic chemicals and MEK (methylethylketon) based printing inks
• Polypropylene (PP) – acids and alkali, detergents, oils, water, organic chemicals
• Polyphenylene sulphide (PPS) – used for more aggressive chemicals, and higher temperatures, up to 120ºC
• Stainless steel – medical and food industries, hydraulic fluids, chemicals, and environments with high temperatures up to 135ºC
• Buna/Nitrophyl – diesel, oil, petrol and water (stationary applications)
• D300 foam (PVC) – mostly for hydraulic oils and chemical solutions
• Polypropylene (PP) – acids and alkali, detergents, oils, water, organic chemicals
• Polyphenylene sulphide (PPS) – used for more aggressive chemicals, and higher temperatures, up to 120ºC
• Stainless steel – medical and food industries, hydraulic fluids, chemicals, and environments with high temperatures up to 135ºC
• Buna/Nitrophyl – diesel, oil, petrol and water (stationary applications)
• D300 foam (PVC) – mostly for hydraulic oils and chemical solutions
Electrical
You need to fully understand what is the nature of the load that requires to be switched and make sure that the float switch is adequate for holding your load. The electrical ratings, which we provide in specifications are resistive loads.
Cables
In areas where harsh liquids may spill onto external wiring, it is important to underline particular materials for the cables in connection to the float switches. You can either use standard, UL-approved cable types for the range of float switches, as well as high temperature, low smoke zero halogen (LSZL) and other specialised materials.
Is this the right switch for you?
The SSF67A25B300 has been designed to give user a long reach float switch with a number of switching options, to cater for a wide variety of system requirements such as aggressive liquids, hygienic applications, petrochemical, storage and process control applications.
Remember!
The cable entry point must NOT under any circumstances be submerged.
屬性 | 值 |
---|---|
Device Type | Float |
Mounting Type | Vertical |
Switch Output | NO/NC |
Body Material | Stainless Steel |
Cable Length | 1m |
Minimum Operating Temperature | -20°C |
Maximum Operating Temperature | +135°C |
Maximum AC Voltage | 250V |
Maximum DC Voltage | 120V |
Maximum Current | 600 mA |
Maximum Pressure | 10bar |
Gasket Material | Nitrile |
Series | SSF67 |