Block 400 VA Chassis Mount Transformer, 2 x 115 V ac, DIN EN 61558-2-6, IEC 61558-2-2, DIN EN 61558-2-4, EN 61558-2-2,
- RS庫存編號:
- 123-7390
- 製造零件編號:
- STEU 400/23
- 製造商:
- Block
小計(1 件)*
TWD4,342.00
(不含稅)
TWD4,559.10
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 加上 3 件從 2026年2月23日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD4,342.00 |
* 參考價格
- RS庫存編號:
- 123-7390
- 製造零件編號:
- STEU 400/23
- 製造商:
- Block
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Block | |
| Primary Voltage | 230 V, 400 V ac | |
| Product Type | Chassis Mount Transformer | |
| Secondary Voltage | 2 x 115 V ac | |
| Power | 400VA | |
| Maximum Operating Temperature | 40°C | |
| Minimum Operating Frequency | 50Hz | |
| Depth | 104mm | |
| Weight | 5.3kg | |
| Series | STEU | |
| Width | 120 mm | |
| Maximum Operating Frequency | 60Hz | |
| Standards/Approvals | DIN EN 61558-2-6, IEC 61558-2-2, DIN EN 61558-2-4, EN 61558-2-2, VDE 0570 Teil 2-2, CSA 22.2 No.66, UL 5085-1/-2, VDE 0570 Part2-4, VDE 0570 Teil 2-6, IEC 61558-2-4, EN 61558-2-4, IEC 61558-2-6, DIN EN 61558-2-2, EN 61558-2-6, cURus | |
| 選取全部 | ||
|---|---|---|
品牌 Block | ||
Primary Voltage 230 V, 400 V ac | ||
Product Type Chassis Mount Transformer | ||
Secondary Voltage 2 x 115 V ac | ||
Power 400VA | ||
Maximum Operating Temperature 40°C | ||
Minimum Operating Frequency 50Hz | ||
Depth 104mm | ||
Weight 5.3kg | ||
Series STEU | ||
Width 120 mm | ||
Maximum Operating Frequency 60Hz | ||
Standards/Approvals DIN EN 61558-2-6, IEC 61558-2-2, DIN EN 61558-2-4, EN 61558-2-2, VDE 0570 Teil 2-2, CSA 22.2 No.66, UL 5085-1/-2, VDE 0570 Part2-4, VDE 0570 Teil 2-6, IEC 61558-2-4, EN 61558-2-4, IEC 61558-2-6, DIN EN 61558-2-2, EN 61558-2-6, cURus | ||
- COO (Country of Origin):
- DE
Block STEU Series Isolating Transformers
BLOCK STEU series isolating transformers with a dual input of 230 and 400 Vac, These safety transformers have a high performance for the volume due to their compact design. The transformers are quick to cable up due to the use of spring clamp terminals, they are also simple to mount with their robust metal footplate with oval slots.
Features
Dual input Voltage
Good switch on behaviour due to reduced starting currents
Excellent corrosion protection
Low Noise
Contact protected screw connection terminals complying with UVV BGV A3
Applications
An isolating transformer for safe electrical isolation of the input and out put sides. The Transformer is suitable for creating SELV and PELV because of the limit on the output voltage. The construction of the transformer can supply control systems according to VDE0113.
相關連結
- Block 250 VA Chassis Mount Transformer DIN EN 61558-2-4 DIN EN 61558-2-2 IEC
- Block 63 VA Chassis Mount Transformer EN 61558-2-2 UL 5085-1/-2 VDE
- Legrand 1 Output 220 VA Chassis Mount Transformer IEC/EN 61558-2-6 UL506 IEC/EN
- Legrand 1 Output 310 VA Chassis Mount Transformer IEC/EN 61558-2-2IEC/EN 61558-2-4IEC/EN 61558-2-6UL506CSA
- Legrand 630 VA Chassis Mount Transformer IEC/EN 61558-2-2IEC/EN 61558-2-4IEC/EN 61558-2-6UL506CSA C22-2-N°66EN
- Block 160 VA Chassis Mount Transformer UL 5085-1/-2 VDE 0570 Teil 2-2
- Block 2 Output 320 VA Chassis Mount Transformer DIN EN 61558-2-2 EN 61558-2-2, IEC
- Block 2 Output 100 VA Chassis Mount Transformer DIN EN 61558-2-2 CSA 22.2 No.66, EN