Legrand 1 Output 310 VA Chassis Mount Transformer, 115 V, IEC/EN 61558-2-2IEC/EN 61558-2-4IEC/EN 61558-2-6UL506CSA
- RS庫存編號:
- 383-330
- 製造零件編號:
- 6 423 66
- 製造商:
- Legrand
此圖片僅供參考,請參閲產品詳細資訊及規格
可享批量折扣
小計(1 件)*
TWD5,690.00
(不含稅)
TWD5,974.50
(含稅)
訂單超過 $1,300.00 免費送貨
暫時缺貨
- 從 2026年4月13日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 - 9 | TWD5,690.00 |
| 10 - 24 | TWD5,539.00 |
| 25 - 49 | TWD5,423.00 |
| 50 - 99 | TWD5,301.00 |
| 100 + | TWD5,224.00 |
* 參考價格
- RS庫存編號:
- 383-330
- 製造零件編號:
- 6 423 66
- 製造商:
- Legrand
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Legrand | |
| Primary Voltage | 230 to 400 V | |
| Product Type | Chassis Mount Transformer | |
| Secondary Voltage | 115 V | |
| Number of Outputs | 1 | |
| Power | 310VA | |
| Winding Type | Insulated Winding | |
| Fixing Hole Diameter | 11mm | |
| Maximum Operating Temperature | 35°C | |
| Weight | 4.5kg | |
| Depth | 110mm | |
| Length | 105mm | |
| Width | 108 mm | |
| Minimum Operating Frequency | 50Hz | |
| Maximum Operating Frequency | 60Hz | |
| Standards/Approvals | IEC/EN 61558-2-2IEC/EN 61558-2-4IEC/EN 61558-2-6UL506CSA C22-2-N°66EN 61131-2EN 60204-1EN 60439-1 | |
| 選取全部 | ||
|---|---|---|
品牌 Legrand | ||
Primary Voltage 230 to 400 V | ||
Product Type Chassis Mount Transformer | ||
Secondary Voltage 115 V | ||
Number of Outputs 1 | ||
Power 310VA | ||
Winding Type Insulated Winding | ||
Fixing Hole Diameter 11mm | ||
Maximum Operating Temperature 35°C | ||
Weight 4.5kg | ||
Depth 110mm | ||
Length 105mm | ||
Width 108 mm | ||
Minimum Operating Frequency 50Hz | ||
Maximum Operating Frequency 60Hz | ||
Standards/Approvals IEC/EN 61558-2-2IEC/EN 61558-2-4IEC/EN 61558-2-6UL506CSA C22-2-N°66EN 61131-2EN 60204-1EN 60439-1 | ||
- COO (Country of Origin):
- FR
Control Panel Primary 230/400Vac (310 to 1000VA)
Compact, open type control panel transformer
Fully shrouded screw terminals with permanent marking
Detailed product specification permanently marked on front of unit
VA ratings compatible with available protection devices
Dual standard primary winding 230 / 400Vac
Laminated
Note
Mounting clips are not supplied with these products. Transformers up to 160 VA can be clipped to DIN rail using accessory 0044 16, RS stock number 423-2201 or 620-3592 for higher values or directly fixed using screws through the easily accessible fixing points.
Standards
IEC/EN 61 558
相關連結
- Legrand 630 VA Chassis Mount Transformer IEC/EN 61558-2-2IEC/EN 61558-2-4IEC/EN 61558-2-6UL506CSA C22-2-N°66EN
- Legrand Chassis Mount Transformer, IEC/EN 61558-2-2IEC/EN 61558-2-4IEC/EN 61558-2-6UL506CSA C22-2-N°66EN 61131-2EN
- Legrand 2 Output 220 VA Chassis Mount Transformer IEC/EN 61558-2-2IEC/EN 61558-2-4IEC/EN 61558-2-6UL506CSA
- Legrand 2 Output 630 VA Chassis Mount Transformer IEC/EN 61558-2-2IEC/EN 61558-2-4IEC/EN 61558-2-6EN
- Legrand 2 Output 310 VA Chassis Mount Transformer EN 60439-1 IEC/EN 61558-2-6 EN
- Legrand 1 Output 220 VA Chassis Mount Transformer IEC/EN 61558-2-6 UL506 IEC/EN
- Legrand 2 Output 310 VA Chassis Mount Transformer EN 60204-1 IEC/EN 61558-2-4, CSA
- Block 400 VA Chassis Mount Transformer DIN EN 61558-2-6 DIN EN 61558-2-4