SMC Vacuum Ejector, 1.8 mm nozzle, -88 kPa 65 L/min, ZH series

小計(1 件)*

TWD2,278.00

(不含稅)

TWD2,391.90

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 7 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD2,278.00

* 參考價格

RS庫存編號:
280-8177
製造零件編號:
ZH18DSA-10-12-12
製造商:
SMC
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SMC

Product Type

Vacuum Ejector

Maximum Suction Flow

65L/min

Maximum Vacuum Pressure

-88kPa

Nozzle Diameter

1.8mm

Series

ZH

Silencer

No

Vacuum Port Size

12 mm

Maximum Supply Pressure

0.6MPa

Exhaust Port Type

Screw-In

Minimum Operating Temperature

-5°C

Supply Port Size

10 mm

Maximum Operating Temperature

50°C

Standards/Approvals

RoHS

Exhaust Port Size

12 mm

COO (Country of Origin):
JP

SMC Series ZH Vacuum Ejector, 65L/min Maximum Suction Flow, -88kPa Maximum Vacuum Pressure - ZH18DSA-10-12-12


This vacuum ejector provides compact, pneumatic vacuum generation for automation and handling tasks, operating with compressed Air as the pressure medium and designed for panel or box-style installation. It is suited to environments where a small, connection-ready unit supplies vacuum for pick-and-place, suction lifters or component handling within normal industrial temperature ranges.

Features & Benefits


• Nozzle diameter 1.8mm delivering focused suction performance
• Maximum vacuum around -88 kPa enabling Strong Hold capacity
• Supply connection One-touch Ø10 for quick tubing assembly
• Vacuum port One-touch Ø12 allowing direct suction hose fitment
• Exhaust port screw-in metric 12mm for standard silencer or piping
• Operates up to 50 °C for typical industrial ambient conditions

Applications


• Suitable for pick-and-place grippers in electronics assembly
• Ideal for suction-based part transfer in mechanical lines
• Used with vacuum cups for handling delicate components
• Can be used for sheet or film lifting in packaging machines

What pneumatic fittings are required for installation?


Use soft nylon, nylon or polyurethane tubing sized to One-touch Ø10 for the supply and Ø12 for the vacuum and exhaust connections.

How does the unit perform under varying ambient temperatures?


It functions reliably between −5 °C and 50 °C for both the pressure medium and surrounding environment.

What Air flow capability should be expected during operation?


Typical usable flow specified is 65 to 76 L/min (ANR) depending on measurement context and installation configuration.

Is a silencer included with the boxed version?


The box configuration ships without a silencer but provides a screw-in metric exhaust port to accept one if required.