SMC Vacuum Generator, 1 mm nozzle, -100 kPa 85 L/min, ZK2 series

小計(1 件)*

TWD8,478.00

(不含稅)

TWD8,901.90

(含稅)

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2026年5月18日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD8,478.00

* 參考價格

RS庫存編號:
392-165
製造零件編號:
ZK2C10J5PL1A-06
製造商:
SMC
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SMC

Product Type

Vacuum Generator

Maximum Suction Flow

85L/min

Maximum Vacuum Pressure

-100kPa

Nozzle Diameter

1mm

Series

ZK2

Silencer

Yes

Standards/Approvals

RoHS, CE

Exhaust Port Size

6 mm

COO (Country of Origin):
JP

SMC ZK2 Series Vacuum Generator, 44L/min Maximum Suction Flow, -91kPa Maximum Vacuum Pressure - ZK2C10J5PL1A-06


This vacuum generator is a Compact pneumatic ejector designed for automated pick-and-place and handling systems in industrial settings. It combines a two-stage ejector with integrated valves and a pressure sensor option to provide controlled suction for small to medium payloads while operating from a common manifold exhaust.

Features & Benefits


• Max suction flow 44L/min delivers efficient part transfer
• Maximum vacuum pressure -91kPa enables secure grip on components
• Nozzle diameter 1mm supports fine-detail handling
• Supply pressure up to 0.6MPa permits robust plant integration
• Built-in silencer reduces exhaust noise to 66dB for quieter operation

Applications


• Suitable for vacuum gripping of electronic components in pick-and-place machines
• Ideal for mechanical assembly tasks requiring precise suction control
• Used with automated conveyors for component transfer and positioning
• Can be used for testing rigs needing repeatable vacuum application

What electrical supply is required to operate the unit?


It runs from a DC supply between 12 and 24V with ±10% tolerance and accepts up to 10% ripple (p-p).

How is the vacuum level monitored and output to automation controls?


An analogue pressure sensor option provides 1 to 5V output proportional to vacuum from 0 to -101kPa with approximately 1kΩ output impedance.

What environmental limits should be observed during installation?


Operate within 0 to 50°C and 35 to 85% RH without condensation

storage extends to −20 to 70°C with no freezing.

How is serviceability addressed for the suction path?


A nominal 30μm suction filter with 510mm² filtration area is fitted to protect the ejector from particulate ingress.