SMC Vacuum Generator, 1.5 mm nozzle, -91 kPa 67 L/min, ZK2 series

小計(1 件)*

TWD13,058.00

(不含稅)

TWD13,710.90

(含稅)

Add to Basket
選擇或輸入數量
暫時缺貨
  • 2 件從 2026年6月04日 起裝運發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD13,058.00

* 參考價格

RS庫存編號:
392-162
製造零件編號:
ZK2A15K5RWA-06
製造商:
SMC
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SMC

Maximum Suction Flow

67L/min

Product Type

Vacuum Generator

Maximum Vacuum Pressure

-91kPa

Nozzle Diameter

1.5mm

Series

ZK2

Silencer

Yes

Maximum Supply Pressure

0.6MPa

Vacuum Port Size

6 mm

Vacuum Port Type

Plug Connection

Minimum Operating Temperature

+5°C

Supply Port Type

Plug Connection

Supply Port Size

8 mm

Supply Port Thread Standard

PE

Maximum Operating Temperature

+50°C

Standards/Approvals

RoHS, CE

COO (Country of Origin):
JP

SMC ZK2 Series Vacuum Generator, 67L/min Maximum Suction Flow, -91kPa Maximum Vacuum Pressure - ZK2A15K5RWA-06


This vacuum generator is a compact, modular ejector unit designed for industrial automation and pneumatic systems. It provides a controlled vacuum source with integrated valves and a silenced exhaust, intended for use where a small footprint and electronic monitoring are required. The unit accepts a plug-in Air supply and offers a selectable pressure-sensing option with an LED display for straightforward monitoring.

Features & Benefits


• Maximum suction flow 67 L/min for steady component handling
• Nozzle diameter 1.5mm enabling fine vacuum control
• Maximum vacuum pressure -91 kPa for effective hold strength
• Supply pressure capability up to 0.6 MPa to match plant systems
• 8mm supply port with plug connection for quick piping
• 6mm plug connection vacuum port for one‑touch fittings

Applications


• Suitable for pick-and-place of small electronic components
• Ideal for end‑effector vacuum cups on assembly robots
• Used with pneumatic grippers in mechanical handling systems
• Can be used for packaging lines requiring Rapid vacuum cycles
• Suitable for testing rigs that need Compact vacuum sources

What electrical supply does the unit require for sensor operation?


The sensor and valve electronics operate from 12 to 24VDC with reverse-polarity protection and a ripple tolerance of 10% p‑p.

How is the vacuum level monitored and signalled?


A 3½‑digit red LED display shows measured pressure

outputs include a PNP open‑collector for general use and a dedicated valve-control output.

What environmental or durability limits should be observed?


Operate the unit between 5 °C and 50 °C

vibration and shock ratings are 20 m/s² and 100 m/s² respectively.

How fine is the pressure adjustment and repeatability?


The smallest set increment is 0.1 kPa with repeatability of ±0.2% F.S. ±1 digit and display accuracy ±2% F.S. ±1 digit.